My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995-1999
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
8660
>
2300 - Underground Storage Tank Program
>
PR0231161
>
COMPLIANCE INFO_1995-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 3:54:44 PM
Creation date
6/3/2020 9:45:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-1999
RECORD_ID
PR0231161
PE
2361
FACILITY_ID
FA0003726
FACILITY_NAME
fast and easy mart #103
STREET_NUMBER
8660
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
STOCKTON
Zip
95210
APN
079-170-390-000
CURRENT_STATUS
01
SITE_LOCATION
8660 LOWER SACRAMENTO RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231161_8660 LOWER SACRAMENTO_1995-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
448
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
011'r <br />Positive Alarm Indication of any <br />Liquid in Underground Fuel Storage <br />Tank Piping Sumps <br />For 3. 7 .lam TLS -350, &S-350,TLS-300i, <br />TLS -250i and ILS -250 UST Monitoring <br />systems. <br />"E"°twrr'i m=�, <br />E.n 'F:{i PioFIYi"ir"1:' <br />The Veeder-Root Piping Sump Sensor detects the <br />presence of liquid in a UST piping sump. Liquid <br />presence could mean a dangerous line leak. <br />D <br />When the sensor detects liquid, it sends an alarm <br />signal to the TLS console monitor, where both <br />visual and audible built-in alarm indicators immedi- <br />ately identify the location of the problem. You can <br />then quickly take action to help prevent serious <br />safety and environmental problems. <br />For even greater warning capability, the TLS -350R, <br />TLS -350, ILS -350, TLS -300i, TLS -250i and ILS -250 <br />feature internal alarm relays that can also trigger <br />on-site alarms. With the TLS -350R, TLS -350 and <br />TLS -3001, alarm signals from the sump sensor <br />trigger a leak report showing the time and location <br />of the alarm condition. The information is stored in <br />the system's Alarm History and can be printed on <br />the monitor's integral printer, or retrieval remotely <br />through its data communications interface. <br />The Veeder-Root Piping Sump Sensor can be used <br />in the piping sumps of either steel or fiberglass <br />tanks. Each sensor comes with complete hardware <br />for mounting on existing conduit or piping. Only two <br />wires are required to connect the sensor to a TLS <br />or ILS system. <br />®TY <br />DESCRIPTION <br />I <br />Piping Sump Sensor -Assembly <br />2 <br />Mounting Strips <br />1 <br />Watertight Cord Grip <br />3 <br />Screws for mounting <br />
The URL can be used to link to this page
Your browser does not support the video tag.