Laserfiche WebLink
0 SAN JOAQUIN COUNTY 0 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sogov.org/ehd/uhitiii.ht] <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />CONTINUED <br />Facility address: <br />Inspection Date: <br /># <br />Code Section <br />VIOLATION(S) HSC=California Flealth & Safety Code; CCR=California Code of R Fgulations V <br />24 <br />CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; (e) test <br />notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, replacement, <br />calibration, or certification; (f) performed, and failed to affix a tag/sticker on each monitoring equipment <br />component that was certified, repaired, or replaced <br />25 <br />CCR 2638 <br />Annual line leak detector test: (a) not performed; (d) test report not submitted within 30 days (MI) <br />26 <br />HSC 25284.2 <br />Annual spill containment testing not performed <br />27 <br />C CR 263:6(D(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present <br />28 <br />CCR 2661 (9 <br />Repair for tank or piping not tested for tightness within 30 days of completion of the repair (M2) <br />29 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) 1 <br />30 <br />CCR 2643(d) <br />-Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (Mi) <br />31 <br />HSC 25292.5 <br />ELD testing not performed on a system located within 1000' of public well, or failures not repaired and retested <br />32 <br />CCR 2661 <br />Permit to repair UST system not obtained <br />33 <br />HSC 25286(a) <br />Permit to alter monitoring system not obtained <br />34 <br />__ <br />HSC 2529i8(b) <br />Permit to temporarily close UST system not obtained <br />35 <br />HSC 25298(c) <br />Permit to close UST system not obtained <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the UST <br />SC 25299(a)(9) <br />Tampering with or disabling leak detection devices or alarms <br />37 <br />HSC 25298(a) <br />Illegally abandoned UST system <br />38 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least monthly or log not kept <br />39 <br />CCR2�2 �.la . <br />UST system is not compatible with the substance stored <br />I Emergency generator systems I <br />Emerqency generator monitoring system not checked daily or log not kept (MI) <br />!d fuel piping not visually inspected at least monthly or log not kept (Mi) <br />EMD23-02-002REV 12/Og Page UST INSPECTION REPORT <br />Compatibility and permeability requirements: (a) UST system is not compatible with the substance stored; (b) <br />42 <br />CCR 2631.1 <br />results of the compatibility and permeability testing requirements listed in subsections CCR 2631 (b) and (d) for a <br />system installed after July 1, 2004, were not submitted <br />43 <br />HSC 25290.1 (c)(1) <br />_L§l <br />Primary containment not liquid or vapor tight <br />44 <br />HSC 25290.1 (c)(2) <br />Secondary containment not liquid or vapor tight <br />45 <br />HSC 25290.1 (c)(3) <br />Secondary containment not constructed to prevent water intrusion <br />46 <br />HSC 25290.1 (d) <br />Monitoring system not maintained to detect water intrusion into the secondary containment, or the entry of liquid <br />HSC 25290.2(d) <br />or vapor from the primary containment into the secondary containment <br />47 <br />HSC 25290.1 (e) <br />Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial space of the UST <br />system not maintained <br />48 <br />HSC 25290.10) <br />UST system not tested by one of the following methods prior to use: (1) Enhanced leak detection; (2) i <br />HSC 25?22.2 1 <br />pressure test approved by SWRCB; (3) test method deemed equivalent to (1) or (2) by the SWRCB <br />EMD23-02-002REV 12/Og Page UST INSPECTION REPORT <br />