My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1995
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_1995
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2020 4:11:26 AM
Creation date
6/3/2020 9:45:50 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_1995.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
393
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Triangle Environmental , Ing . <br /> 172 West Verdugo Ave. , Burbank, California 91502 <br /> FTA LEAK DETECTOR TEST DATA SHEET <br /> SITE: <br /> G11)Gcz2 l # JO 0 y DATE: 7- 20 <br /> 17U l h/, met,-C W/o #: <br /> 5 TLC toll <br /> Product Serial Humber Drain Trip Test Funct. Tripping Pass <br /> Type Detector Style Back Time Rate Ele. Pressure or <br /> ml sec ml/min psi psi Fail <br /> �^ /� p <br /> DLD PLD� XLP VPR I�vi�C S C 1 �( !'S, (1 <br /> DLD PLD XLD XLP VPR <br /> DLD PLD .XLD XLP VPR <br /> DLD PLD XLD XLP VPR <br /> 1 DLD PLD XLD XLP VPR <br /> DLD PLD XLD XLP VPR <br /> I certify the above tests were conducted on this date according to the <br /> equipment manufacturer's procedures and limitations and the results as listed <br /> are to my knowledge true and correct. J <br /> Technician: �` Lic. # 7 3 <br /> The mechanical Leak Detector Test pass/fail is determined using a low <br /> flow threshold trip rate of 284 ml per minute or less at 10 psi as set <br /> by Red Jacket Pumps Field Test Apparatus testing procedure. <br /> Copyright (c) , Triangle Environmental, Inc. , January 1991. hRL <br />
The URL can be used to link to this page
Your browser does not support the video tag.