Laserfiche WebLink
• IFIED PROGRAM CONSOLIDATED JkM SITE#255886/5886/31010 <br /> ' MW PIPING <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRL CTION(Check all that apply) Page of <br /> UNDERGROUND PIPING D PIPING <br /> SYSTEM TYPE 1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 458 El 1.PRESSURE ❑2.SUCTION ❑3.GRAVITY 459 <br /> ❑ .SINGLE WALL [13.LINED TRENCH [:199.OTHER 460 ❑1.SINGLE WALL ❑95.XERXES 462 <br /> CONSTRUCTION/ DOUBLE WALL [195.XERXES ❑2.DOUBLE WALL ❑99.OTHER <br /> MANUFACTURER <br /> MANUFACTURER 461 MANUFACTURER 463 <br /> [:11.BARE STEEL ❑6.FRP COMPATIBLE Wt loaf°METHANOL [:11.BARE STEEL ❑6.FRP COMPATIBLE W/100%METHANOL <br /> MATERIALS AND ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL <br /> CORROSION ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑95.XERXES ❑3.PLASTIC COMPATIBLE WITH CONTENTS ❑8.FLEXIBLE(HDPE) ❑99.OTHER <br /> PROTECTION 'FIBERGLASS ❑8.FLEXIBLE(HDPE) [199.OTHER [:14. FIBERGLASS [19.CATHODIC PROTECTION <br /> F15.STEEL W/COATING ❑9.CATHODIC PROTECTION 464 ❑5. STEEL W/COATING ❑95. XERXES 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description of the monitoring program shall be submitted to the local agency.) <br /> UNDERGROUNDPIING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> ❑ I ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR ❑ 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT OFF FOR LEAK, <br /> LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL SYSTEM FAILURE,AND SYSTEM DISCONNECTION+AUDIBLE AND VISUAL ALARMS <br /> ALARMS <br /> E] 2. MONTHLY 0.2 GPH TEST 2. MONTHLY 0.2 GPH TEST <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 3. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS: CONVENTIONAL SUCTION SYSTEMS(Check all that apply): <br /> ❑ 5 DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING INTEGRITY ❑ 5. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> TEST(0.1 GPH) ❑ 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING). <br /> ❑ 7. SELF MONITORING ❑ 7. SELF MONITORING <br /> GRAVITY FLOW: GRAVITY FLOW(Check all that apply): <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) ❑ 8. DAILY VISUAL MONITORING <br /> ❑ 9. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING <br /> SECONDARILY CONTAINED PIPING PRESSURIZED PIPING(Check all that apply): <br /> PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL ALARMS AND(check one) <br /> (Check one) ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ❑ a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS ❑ b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM DISCONNECTION <br /> -fR�yb. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM ❑ c. NO AUTO PUMP SHUT OFF <br /> DISCONNECTION ❑ 11. AUTOMATIC LEAK DETECTOR <br /> ❑ c. NO AUTO PUMP SHUT OFF ❑ 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> 1. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT OFF OR <br /> RESTRICTION "6s- <br /> SUCTION/GRAVITY SYSTEM: <br /> " <br /> 12. ANNUAL INTEGRITY TEST(0.1 GPH) dew 6 S• ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> SUCTION/GRAVITY SYSTEM: EMERGENCY GENERATORS ONLY(Check all that apply) <br /> ❑ 13. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND VISUAL <br /> ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> ❑ 14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF+AUDIBLE AND <br /> VISUAL ALARMS ❑ 16. ANNUAL INTEGRITY TEST(0.I GPH) <br /> ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW SHUT OFF OR ❑ 17. DAILY VISUAL CHECK <br /> RESTRICTION <br /> ❑ 16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> ❑ 17. DAILY VISUAL CHECK <br /> VIII.DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT 1.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑ 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS ❑ 5.TRENCH LINER/MONITORING <br /> ❑ 3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR DISPENSER+AUDIBLE AND VISUAL ALARMS ❑ 6.NONE 469 <br /> IX.OWNER/OPER#TOR SIGNATURE <br /> I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> SIGNA R OF OWNER/ TOR DATE 470 <br /> AM, �--- (3 oda.. <br /> NAME OF ER/OPERATOR(print) 471 TITLE OF OWNEPkPFPERATOR 472 <br /> JANETTE M.THOMPSON FOR CIRCLE K STORES,INC. COMPLIANCE SPECIALIST <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) 474 1 Permit Expiration Date(For local use only)475 <br />