My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_1996-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 3:54:32 PM
Creation date
6/3/2020 9:45:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2003
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_1996-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i IED PROGRAM CONSOLIDATED FOR <br /> TANKS <br /> UNDERGROUND STORAGE TANKS-TANK PAGE 1 <br /> (two pages per tank) <br /> Page_of- <br /> TYPE <br /> f_TYPE OF ACTION ❑1.NEW SITE PERMIT ❑4.AMENDED PERMIT ❑5. CHANGE OF INFORMATION) ❑6.TEMPORARY SITE CLOSURE <br /> (Check one item only) ❑7. PERMANENTLY CLOSED ON SD'E <br /> ❑3.RENEWAL PERMIT El 8.TANK REMOVED 430 <br /> (Specify reason-for local use only) (Specify change-for local use only) <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 FACILITY ID# 1 <br /> ConocoPhillips, Site#255886/5886 <br /> LOCATION WITHIN SITE(Optional) 431 <br /> L TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑ Yes ® No 434 <br /> 1 OOR If OYesO,complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1995 15,000 0 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑ 2. LEADED ❑ 5. JET FUEL <br /> (Ifmarked,complete Petroleum Type) ❑Ib. PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ic. MIDGRADE UNLEADED ❑ 4.GASOHOL ❑99. OTHER <br /> ❑3. CHEMICAL PRODUCT <br /> ❑ 4.HAZARDOUS WASTE(Includes <br /> Used Oil) COMMON NAME(from Hazardous Materials Inventorypage) 441 CAS#(from Hazardous Materials Inventorypage) 442 <br /> ❑95. XERXES <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑ 3. SINGLE WALL WITH ❑ 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) ® 2. DOUBLE WALL EXTERIOR MEMBRANE LINER ❑95.XERXES <br /> ❑ 4. SINGLE WALL IN A VAULT [199.OTHER <br /> TANK MATERIAL-primary tank ®1.BARE STEEL [33.FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. XERXES 444 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASs ❑8. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC RP <br /> TANK MATERIAL-secondary tank [:11. BARE STEEL ❑3.FIBERGLASS/PLASTIC ❑8. FRP COMPATIBLE W/100%METHANOL ❑95.XERXES 445 <br /> (Check one item only) ❑2.STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS ❑9.FRP NON-CORRODIBLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1. RUBBER LINED ❑3. EPDXY LINING ❑5.GLASS LINING 095. XERXES 446 DATE INSTALLED 447 <br /> OR COATING ❑2.ALKYD LINING 04. PHENOLIC LINING 06.UNLINED ❑99. OTHER <br /> Check one item only) or local use only) <br /> OTHER CORROSION ❑I.MANUFACTURED ®3.FIBERGLASS REINFORCED PLASTIC ❑95. XERXES 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE CATHODIC <br /> 04.IMPRESSED CURRENT ❑99.OTHER <br /> PROTECTION <br /> (Check one item only) ❑2. SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(For local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) 01. SPILL CONTAINMENT 2002 ❑1.ALARM 03. FILL TUBE SHUT OFF VALVE_1996 <br /> ®2. DROPTUBE 1996 El 2. BALL FLOAT El 4. EXEMPT <br /> ®3. STRIKER PLATE 1995 <br /> IV. TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply): 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER(Check one item only): 454 <br /> ❑1, VISUAL(EXPOSED PORTION ONLY) ❑5. MANUAL TANK GAUGING(MTG) ❑1. VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6. VADOSE ZONE ®2. CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3. CONTINUOUSATG ❑7. GROUNDWATER ❑3. MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION(SIR)+ ❑8. TANKTESTING <br /> BIENNIAL TANK TESTING F-199. OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> eallons ❑Yes ❑No <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.