My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2007-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:06:45 PM
Creation date
6/3/2020 9:46:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2009
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2007-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DEC-26-2007 13:25 Service Station Systems 408 938 8888 P.03 <br /> Softwarc version installed: 3 <br /> copeete the followin checklist: <br /> Wis the audible alarm o erational? <br /> Is the visual alarm Operational? <br /> Were all sensors visual) ins ceted,functional) tested,and confirmed o rational? <br /> Were all sensors installed at lowest paint of secondary containment and positioned so that other equipment will <br /> not interfere with their er o ration? <br /> if alarms arc relayed to a remote monitoring station, is all communications equipment (e.g. )modem) <br /> O N/A operational? <br /> Yes ® No* For pressurized piping systems,does the turbine au uatically shut down if the piping secondary containmment <br /> Cl N/A monitoring system detects a leak,fails to opera ,oris electrically disconnected? If yes: ch sensors initiate <br /> positive shut-clown? (Check all that apply) Sump/Trencb Sensors, Q Dispenscr ` tainment Sensors. <br /> Di ou confirm ositive shut-down due to leaks and sensor failurc/disconnection? Yes; ®No. <br /> Yes ® No* kor tank systems that utilize the monitoring system as the primary tank overfill warning device (i;e. no <br /> Q N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> f int(s) and. operating properly? If so, at what percent of Lair), capacity does the alarm trigger? <br /> ® Yes* No Was any monitoring equipment replaced? if yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement arts in Section E below. <br /> ® Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> 0 product; 0 Water. If yes,describe causes in Section E,bclaw. <br /> 9s 13 No* Was monitorin s stem set-up reviewed to ensure Proper settings?Attach set tip rcpots,if applicable <br /> Yec ui meat o tional ger manufacturer's cifrcations? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E, Comments' <br /> Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.