My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2007-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:06:45 PM
Creation date
6/3/2020 9:46:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2009
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2007-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
323
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />Zip n <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />TEST DATE: 04/27/07 AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2248765 <br />CLIENT: CONOCO-PHILLIPS SITE:CONOCO PHILLIPS #255886 <br />Tank ID: 3 <br />Product: DIESEL <br />Capacity in gallons: 12,032 <br />Diameter in inches: 95.00 <br />Length in inches: 397 <br />Material: DW FIBERG <br />COMMENTS <br />PSI at tank bottom: <br />Fluid level in inches: <br />UFT/OFT: <br />Fluid volume in gallons: <br />Tank water level in inches: <br />Test time: <br />Number of thermisters: <br />Specific gravity: <br />Water table depth in inches: <br />Determined by (method): <br />Leak rate in gph: <br />Result: <br />COMMENTS <br />Test time: <br />Ullage volume: <br />Ullage pressure: <br />Results: <br />Tank manifolded: YES <br />Vent manifolded: YES <br />Vapor recovery manifolded: YES <br />Overfill protection: YES <br />Overspill protection: YES <br />Installed: ATG <br />CP installed on: / / <br />Bottom to top fill in inches: <br />Bottom to grade in inches: <br />Fill pipe length in inches: <br />Fill pipe diameter in inches: <br />Stage I vapor recovery: <br />Stage II vapor recovery: <br />DUAL <br />ASSIST <br />New/passed Failed/replaced New/passed Failed/replaced <br />L.D. #1 L.D. #1 L.D. #2 L.D. #2 <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Test 1: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 2: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 3: Start time: <br />Finish psi: <br />Vol change cc: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />300.0 <br />NOT <br />TESTED <br />VAPORLESS <br />LD2000 <br />47631 <br />NOT <br />TESTED <br />3.00 <br />FAIL <br />PRESSURE <br />RED JACKET <br />Impact Valves Operational: YES <br />NOT <br />TESTED <br />NOT NOT <br />TESTED TESTED <br />Printed 05/08/2007 08:26 ACRAMER <br />Make: <br />VAPORLESS <br />Model: <br />LD2000 <br />S/N: <br />65209 <br />NOT <br />Open time in sec: <br />5.00 <br />TESTED <br />Holding psi: <br />31 <br />Resiliency cc: <br />120 <br />Test leak rate ml/m: <br />189.0 <br />Metering psi: <br />14 <br />Calib. leak in gph: <br />3.00 <br />Results: <br />PASS <br />COMMENTS <br />DATA FOR UTS-4T ONLY: <br />Time of test 1: <br />Temperature: NOT <br />Flow rate (cfh): TESTED <br />Time of test 2: <br />Temperature: <br />Flow rate (cfh): <br />Time of test 3: <br />Temperature: <br />Flow rate (cfh): <br />COMMENTS <br />Material: <br />Diameter (in): <br />Length (ft): <br />Test psi: <br />Bleedback cc: <br />Test time (min): <br />Test 1: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 2: Start time: <br />Finish psi: <br />Vol change cc: <br />Test 3: Start time: <br />Finish psi: <br />Vol change cc: <br />Final gph: <br />Result: <br />Pump type: <br />Pump make: <br />COMMENTS <br />DW FIBERG <br />2.0 <br />300.0 <br />NOT <br />TESTED <br />VAPORLESS <br />LD2000 <br />47631 <br />NOT <br />TESTED <br />3.00 <br />FAIL <br />PRESSURE <br />RED JACKET <br />Impact Valves Operational: YES <br />NOT <br />TESTED <br />NOT NOT <br />TESTED TESTED <br />Printed 05/08/2007 08:26 ACRAMER <br />