My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MARCH
>
2701
>
2300 - Underground Storage Tank Program
>
PR0231176
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2023 4:14:10 PM
Creation date
6/3/2020 9:46:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231176
PE
2361
FACILITY_ID
FA0003798
FACILITY_NAME
MARCH LANE 76*
STREET_NUMBER
2701
Direction
W
STREET_NAME
MARCH
STREET_TYPE
LN
City
STOCKTON
Zip
95219
APN
11619007
CURRENT_STATUS
01
SITE_LOCATION
2701 W MARCH LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231176_2701 W MARCH_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
356
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground!Storage Tank Program Inspection Rep©rt' <br /> > . <br /> Facility Name: Facility Address: Date: <br /> MARCH LANE 76'" 2701 W MARCH LN, STOCKTON December 15, 2016 <br /> SUMMARY OF VIOLATIaNS <br /> tdLASS t,GLASS il,orMINOR-:Notice to Comply) <br /> x <br /> Item# Remarks <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days. <br /> A new designated operator, Brian McPheely, was listed as the designated operator on the 10/11/16, 11/9/16 and <br /> 12/7/16 designated operator reports and notification was not provided to the EHD within 30 days of the change. Any <br /> changes shall be reported to the EHD within 30 days. The notification identifying all of the designated operators for <br /> this facility was uploaded into the California Environmental Reporting System (CERS). <br /> This was corrected on site. <br /> This is a minor violation. <br /> 205 CCR 2712(i) Failure to have an approved UST response plan available onsite. <br /> The Response Plan was not found on site during the inspection. The Response Plan was downloaded from California <br /> Environmental Reporting System (CERS) and a copy was placed in the file at the facility. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept. <br /> The designated operator employee training for Tiffany Fite and Tia Fite did not include the "Hire Date". The <br /> designated operator shall train facility employees for which he or she is responsible in the proper operation and <br /> maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br /> 1. Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person(s)for emergencies and monitoring equipment alarms <br /> The "Hire Date"was added for the two employees during the inspection. <br /> This was corrected on site. <br /> This is a minor violation. <br /> 309 CCR 2636(f)(1) Monitoring in sump/ UDC failed to activate an audible and visual alarm or stop the flow product. <br /> The diesel Bravo box float and chain in the 9/10 under dispenser containment(UDC) failed to stop the flow of product <br /> at the dispenser when tested. The diesel Bravo box chain was adjusted, retested, and passed. All monitoring <br /> equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the dispenser <br /> when it detects a leak. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 14, 2017. <br /> FA0003798 PR0231176 SCO01 12/15/2016 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.