My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2003-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 2:32:22 PM
Creation date
6/3/2020 9:46:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2008
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2003-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
347
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 <br /> (Two pages per tank) <br /> Page of_ <br /> 51 <br /> TYPE OF ACTION 06 1.NEW PERMIT ❑ 4.AMENDED PERMIT ❑ 5.CHANGE OF INFORMATION ❑ 6.TEMPORARY TANK CLOSURE 430. <br /> (Check one item only) ❑ 3.RENEWAL PERMIT ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Spenifyroason) (Specify-) ❑ 8.TANK REMOVED <br /> BUSINESS NAME(SamcasFACILITY NAME orDBA-Doing Business As) 3. I FACILITY ID: 1 <br /> Cta; i/1 I® + <br /> LOCATION WITHIN SITE(optimal) 431. <br /> I.TANK DESCRIPTION <br /> A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432. TANK MANUFACTURER 433. COMPARTMENTALIZED TANK Ll Yes No 434. <br /> (VIern WeA it/1,. If"Yes,^complete one page for each comlmitn nt. <br /> DATE INSTAL D 435. TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS <br /> (YEAR/MO) 437. <br /> 91000 t <br /> ADDITIONAL DESCRIPTION(Forbcal use only) 43A <br /> U.TANK CONTENTS <br /> TANK USE 439• PETROLEUM TYPE 440. <br /> I. MOTOR VEHICLE FUEL ❑la. REGULAR UNLEADED ❑2. LEADED ❑S. JET FUEL <br /> (ifchecked,cornpletc Petroleum Type) &M PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑lc. MIDGRADE UNLEADED [14. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON Nt1N1E(from Hazardous materials inventory page) 441' CAS#(from Hazardous Materials inventory page) 4-42. <br /> ❑ 4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR [IS. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) �/ MEMBRANE LINER ❑95. UNKNOWN <br /> $2 DOUBLE WALL ❑4. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank . BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95.UNKNOWN 444. <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC(FRP) W/100°/METHANOL <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ❑3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑I.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447. <br /> OR COATING N A ❑2.ALKYD LINING ❑4.PHENOLIC LINING ❑6.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION L 1.MANUFACTURED CATHODIC 913.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 449. DATE INSTAILED 449. <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER PrQp4 <br /> (IfA licable) 2.SACRIFICIAL ANODEQ QQ3 <br /> SPILL AND OVERFILL YEAR INS ALLED 450. TYPE 451. OV FILL PROTECTION EQUIPMENT: YEAR INSTALLE 452. <br /> (Check all that apply) RrI.SPILL CONTAINMENT 01 ALARM FILL TUBE SHUT OFF VALVE <br /> M�1.DROP TUBE t `• g�(( ❑2.BALL FLOAT ❑4.EXEMPT <br /> STRIKER PLATE !• !e t�t1/1 <br /> IV.TANK LEAK DETEC ON <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453. IF DOUBLE WALL TANK OR TANK WITH BLADDER 454. <br /> (Check all that apply) (Check one item only) <br /> ❑1.VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> [12.AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4.STATISTICAL INVENTORY RECONCILIATION ❑8.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455. ESTIMATED QUANTITY OF SUBSTANCE REMAININGTANK FILLED WITH INERT MATERIAL? 457. <br /> gallons ❑Yes ❑ No <br /> UPCF hwfwre-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.