Laserfiche WebLink
Designat nderground Storage Tank (UST) rator <br /> onthly Visual Inspection Checklist <br /> Facilit Name: EPA'S CAR WASH NORTH <br /> a Facili Address:6230 PACIFIC AVE Date:December 28,2005 <br /> Cl :STOCKTON State:CA <br /> ZIP Code:95207 <br /> Designated UST Op ator Conducting the Inspection: Ron Sanchez <br /> International Co ouncil Certification#:5248997-UC Expiration Date: December 16th,2006 <br /> Signature: (/ <br /> ir'.. Date:December 28,2005 <br /> ItemY=Yes N= No NA=Not A licable <br /> Monitoring Panel/Alarm History Y N NA <br /> 1. Monitoring system is powered on and in proper operating mode? <br /> X <br /> 2. Monitorin <br /> g system is NOT currently showing any alarms or warnings? X <br /> 3. Alarm history report/log for the previous month is available,and has been reviewed by X <br /> the Designated UST Operator?(Attach a copy of the alarm report/log to this form if <br /> available <br /> 4. Each alarm for the previous month has been responded to appropriately? X <br /> S. Sensors located in tank-top containment sumps have NOT alarmed in the past month? X <br /> Sa. List all tank-top sumps where alarms occurred in the past month. <br /> Note:Sumps where an alarm has occurred in the past month must be inspected unless a qualified service technician responded to, <br /> and properly addressed the cause of the alarm.Attach documentation verifying appropriate service to this report.if sump <br /> Ins ection is required.put in item 6. <br /> UST System Inspection <br /> 6. Tank-top containment sumps are free of water,debris,and hazardous substance.Sensors are located properly. <br /> Note:Visual inspection of sumps is only required in sumps where an alarm has occurred in the past month for which there is no <br /> service record. <br /> Y N Y N <br /> Sum Location UNLEADED X Sum Location PLUS <br /> Sum Location DEISEL X Sum Location SUPREME X <br /> Sum Location X <br /> 7. Spill containment structures are free of water,debris,and hazardoustion substance? <br /> Y N NA Y N NA <br /> Tank 1.Contents UNLEADED X Tank J.Contents PLUS <br /> Tank 2.Contents DEISEL X X <br /> Tank 4.Contents SUPREME X <br /> 8. Under-dis enser containment areas are free of water,debris,&hazardous substance?Sensors are workinro erl <br /> Y N NA Y N NA <br /> Dis enser 1&2 X Dis enser 9&10 <br /> Dis nser 3&4 X X <br /> Dispenser 5&6Dis enser I I &12 X <br /> X Dispenser 13&14 X <br /> Dispenser 7&8 X Dispenser 15&16 <br /> Paperwork Inspection Y N NA Date <br /> 9. Monitoring system certification has been completed within past 12 months? X Done <br /> 10. Secondary containment tests have been completed within required timeframe? X 7/05 <br /> 11. Spill containment structure(bucket)testing was completed in the past year? X 8/05 <br /> 12. Tank tightness testing was completed within required timeframe? 8/05 <br /> X 8/05 <br /> 13. Line tightness testing was completed within required timeframe? <br /> X 8/05 <br /> 14. Other required testing/maintenance was completed within required timeframe.(List test/maintenance items below.) <br /> Test Maintenance <br /> Test Maintenance <br /> Test Maintenance <br /> Facility Employee Training Y N NA Date <br /> 15. All employees have received the required on the job training within the past year? X Done <br /> 8/05 <br /> 16. All employees hired within 30 days have received the required on the job <br /> training? X <br /> Note:Any answer of"N-should be explained in the comment section on the following page,and will require follow-up action. <br />