Laserfiche WebLink
D. Results of Testing/Servicing <br /> Software Version Installed: 329.01 <br /> om lete the foll Ing checklist: <br /> ® Yes ❑ No* is the audible alarm operational? <br /> ® Yes ❑ No* Is the visual alarm operational? <br /> ® Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operational? <br /> ® NIA <br /> ® Yes ❑ No* For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system detects a <br /> ❑ N/A leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-down? (Check all that apply) <br /> Sumprfrench Sensors; ®Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks gad sensor failure/disconnection? ®Yes; []No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.,no mechanical overfill prevention valve is <br /> ® N/A installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank <br /> capacity does the alarm trigger? 0% <br /> ❑ Yes* iSl No Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the manufacturer <br /> name and model for all replacement parts in Section E,below. <br /> ❑ Yes* ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑Water. if yes,describe causes in Section E,below. <br /> ® Yes ❑ No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ® Yes ❑ No` Is all monitoring equipment operational per manufacturer's specifications? <br /> *in Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: INSPECTOR HAS ALL PRINT OUTS <br /> Monitoring System Certification Page 2 of 4 2/21/07 <br /> l <br />