My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
6230
>
2300 - Underground Storage Tank Program
>
PR0231225
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2020 11:53:20 PM
Creation date
6/3/2020 9:46:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231225
PE
2361
FACILITY_ID
FA0003624
FACILITY_NAME
CANEPAS CAR WASH
STREET_NUMBER
6230
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
08136003
CURRENT_STATUS
01
SITE_LOCATION
6230 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231225_6230 PACIFIC_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
419
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑Repair Inspection 9 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181251 8/29/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> CANEPAS CAR WASH <br /> Business Site Address 3TOCKTON <br /> y ZIP Code <br /> 6230 PACIFIC AVE CA 95207 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the/CC Certification.) Phone# <br /> David Winkler (209) 744-0112 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 08-1739 Ex.3/31/2020 8883059-UT 1/29/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> FF- EBW , Phil-Tite & EVR Phase 1 1009853708 Ex 11-16-18 OPW 104-633 Ex 3-14-2 0 <br /> Emco #3207 Ex. 09-21-2020 VR: B34975 ATG:2/8/20 <br /> xfi .; <br /> Ill. OVERFILL PREVENTION EQUIPMENT INSPECTION N <br /> Inspection Method ❑x Manufacturer Guidelines(Specify): <br /> Used: Removed Drop Tubes N0''' 3 0 x°018 <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): I v <br /> TM :N.T <br /> Attach the inspection procedures and all documentation required to determine the results. 46fAttached Pages 10 <br /> TANK ID:(By tank number,stored product,etc.) 87S 87 N 91 DSL <br /> What is the tank inside diameter?(Inches) 95.25 95.25 95.25 95.25 <br /> Is the fill piping secondarily contained? ❑Yes 0 No ❑Yes 0 No ❑Yes ❑x No ❑Yes ❑x No <br /> Is the vent piping secondarily contained? ❑Yes ®No ❑Yes El No ❑Yes [j]No ❑Yes ❑x No <br /> Overfill Prevention Equipment Manufacturer(s) oPw oPw OPw EMCO <br /> 61-SO 61-SO 61-SO 1100 <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow [E Shuts Off Flow ®Shuts Off Flow <br /> when activated? <br /> ❑ <br /> (Check all that apply.) Restricts Flow El Restricts Flow El Restricts Flow E]Restricts Flow <br /> ❑A/V Alarm ❑A/V Alarm ❑AN Alarm ❑A/V Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ❑x No ❑Yes [E No ❑Yes R No ❑Yes ®No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 8611 8611 <br /> 8611 <br /> 64.5„ <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 95 95 95 72% <br /> Is the overfill prevention in proper operating condition ®Yes ❑D Yes El Yes n Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) ❑No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ®Pass ❑Fail I ❑x Pass ❑Fail ❑x Pass ❑Fail ❑x Pass ❑Fail <br /> V. COMMENTS <br /> Any items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signature <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Reporting System,ID=Identficalion,UST=Underground Storage Tank,ICC=International Code Council,AN=Audible and Usual <br />
The URL can be used to link to this page
Your browser does not support the video tag.