My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1996
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231289
>
COMPLIANCE INFO_1986-1996
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/23/2023 1:43:38 PM
Creation date
6/3/2020 9:46:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1996
RECORD_ID
PR0231289
PE
2361
FACILITY_ID
FA0003847
FACILITY_NAME
WEST LANE FUEL
STREET_NUMBER
3300
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11705037
CURRENT_STATUS
01
SITE_LOCATION
3300 N WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231289_3300 N WEST_1986-1996.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If <br />contamination is documented during closure, an Unauthorized Reiease Notification must be completed and submitted within five <br />(5) working days pursuant to California Health & Safety Code, Section 25295. <br />TANK TANK SIZE <br /># (Gallons) <br />< 1,000 <br />t-3 1, 000 - 10, 000 <br />> 10,000 <br />WATER NOT PRESENT IN THE TANK PIT <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />1 per Tank <br />2 per Tank <br />3 or More <br />per Tank <br />LOCATION OF SOIL SAMPLES <br />Fill OR Pump End of Tank <br />1 at each End of Tank <br />Ends and Middle OR senerally <br />spaced along the length of the Tank <br />PIPING AND STOCKPILE <br />�v n To oovcvv, T TN TANY PTT <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order <br />to collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK SIZE <br />MINIMUM NUMBER <br />LOCATION of SOIL <br />NILNIMUM NUMBER of <br />TANK <br />n <br />(Gallons) <br />of SOIL SAMPLESSAMPLES <br />WATER SAMPLES <br />< 10,000 <br />5 per Tank <br />From wall next to tank <br />> 10,000 <br />Single Tank <br />2 <br />ends at soil/ groundwater <br />1 <br />interface <br />From wall next to tank <br />> 10,000 OR <br />Tank Cluster <br />4 <br />ends at soil/ <br />1 <br />groundwater interface <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order <br />to collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />EH 23 046 (Revised 7/10/96) Page 7 <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />TANK <br /># <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />< 1,000 <br />1,000 - 10,000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced along <br />the length of the Tank <br />EH 23 046 (Revised 7/10/96) Page 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.