My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2007
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231289
>
COMPLIANCE INFO_1997-2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2024 2:08:30 PM
Creation date
6/3/2020 9:46:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2007
RECORD_ID
PR0231289
PE
2361
FACILITY_ID
FA0003847
FACILITY_NAME
WEST LANE FUEL
STREET_NUMBER
3300
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11705037
CURRENT_STATUS
01
SITE_LOCATION
3300 N WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231289_3300 N WEST_1997-2007.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUINPUBLIC HEALTH SERVICES/ENVIRONMENTAL H VISION <br /> I, t 0 WORKSHEET FOR SITE CLOSURE EVALUATION DATE <br /> NAME OF FACILITY l SWEEPS CODE <br /> ADDRESS TANK ID # - <br /> TANK SIZE g FUEL TYPE L. <br /> II. GENERAL SITE HISTORY <br /> Is permit current? Yes No Permit # Facility Status Code Doc.SoiL/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel Fbrgl Sng! Dual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give date(s) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Pb/EDB <br /> Type of failure/discharge catastrophic tong-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples ReceivedI :Yes No Depth to Ground Water Ref/Year Average l Precipitation A= 14 .10-25 <br /> (On-Site Well s) Yes No Number & Type Irr I Dan Pub <br /> S Score S Score S Score <br /> Distance to WelL(s) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potentia! Analysis E is met E is met E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> 4Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxxxxx None one — one <br /> COLUMN TOTALS>»TOTAL POINTS + ( + _ <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> BT X E B T X E <br /> JMAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sample Result: GASOLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPN LEVELS (PPM) <br /> TPH DIESEL 10,000 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do rot complete the Leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPN concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are BTX & E or TPH Concentrations > Allowable Levels *Yes No <br /> 2. Recommend Site Closure Yes No *If Yes, Refer to Site Mitigation for Evaluation <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YESI NO <br /> DATE REFERREDI DATE CLOSURE LETTER MAILED ! / <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 40 <br />
The URL can be used to link to this page
Your browser does not support the video tag.