Laserfiche WebLink
IED PROGRAM CONSOLIDATED FOR TANK: TA0506059 <br /> PR#: PR0231333 <br /> UNDERGROUND STORAGE TANKS -TANK PAGE 1 FAC#: FA0003711 <br /> (two pages per tank) <br /> TYPE OF ACTIONPage 6 of 7 <br /> ❑ 1 NEW SITE PERMIT ❑4 AMENDED PERMIT �5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check only item only) <br /> } ,�� „lli ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT :...s ❑8 TANK REMOVED 430 <br /> 10-0-� �. x_. - <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: 1 <br /> LAKEWOOD CHEVRON USA#4183* 3 FA0003711 PR0231333 <br /> LOCATION WITHIN SITE(Optional) 236 N HAM LN,LODI 431 <br /> PHONE <br /> 1.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 7 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ❑No 434 <br /> TA0506059 XERXES If"Yes",complete one page for each comparmtent. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 12,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ❑X 1.MOTOR VEHICLE FUEL ® 1 a.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked complete Petroleom Type) <br /> ❑ lb.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑3.CHEMICAL PRODUCT <br /> COMMON NAME(from Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) <br /> 4.HAZARDOUS WASTE i1 aa2 <br /> E] 4. <br /> Used oil) MID GRADE <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> © 2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ❑FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ® 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ L BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED <br /> OR COATING ❑ 3.EPDXY LINING ❑ 5.GLASS LINING E]95.UNKNOWN 446 DATE INSTALLED 447 <br /> (Check one item only) ❑ 2 ALKYD LINING ❑4 PHENOLIC LINING ❑ 6 UNLINED ® 99.OTHER <br /> FRP (For local use only) <br /> OTHER CORROSION ❑ 1 MANUFACTURING CATHODIC 0 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑4 IMPRESSED CURRENT ❑ 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILLYEARYEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> `tel <br /> (Check all that apply) I SPILL CONTAINMENT0110 ❑ t [v <br /> 2 DROP TUBE qu <br /> ALARM 3 FILL TUBE SHUT OFF VAL` v <br /> ❑ 2 BALL ❑ 4 EXEMPT <br /> b ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ©2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br /> (SIR)BIENNIAL TANK TESTING 99 OTHER E]3 MANUAL MONITORING <br /> ❑ <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />