My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
236
>
2300 - Underground Storage Tank Program
>
PR0231333
>
COMPLIANCE INFO_1997-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2024 2:31:42 PM
Creation date
6/3/2020 9:46:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2012
RECORD_ID
PR0231333
PE
2361
FACILITY_ID
FA0003711
FACILITY_NAME
LAKEWOOD CHEVRON
STREET_NUMBER
236
Direction
N
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03710028
CURRENT_STATUS
01
SITE_LOCATION
236 N HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231333_236 N HAM_1997-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix VI <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use B All Jurisdictions Within the State of California <br /> Y �/ <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3,Title 23,California Code of Regu atio <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or r e prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provid stem <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems wit i <br /> A. General Information <br /> Facility Name: LAKEWOOD CHEVRON Bldg.No.: <br /> Site Address: 236 HAM LANE City: LODI Zip: 95240 <br /> Facility Contact <br /> Ppranrc RUPI Contact Phone No.: (209)333-6303 <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 10-22-2012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: 87 Tank ID: 91 <br /> ® In-Tank Gauging Probe. Model: MAG 1 ® In-Tank Gauging Probe. Model: MAG 1 <br /> ® Annular Space or Vault Sensor. Model: 409 ® Annular Space or Vault Sensor. Model: 409 <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ® Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: El Fill Sump Sensor(s). Mcdel: <br /> ® Mechanical Line Leak Detector. Model: LD 2000 ® Mechanical Line Leak Detector. Model: LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: DIE Tank ID: <br /> ® In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> ® Annular Space or Vault Sensor. Model: 409 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 6-6 Dispenser ID: 7-8 <br /> ® Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: 208 <br /> ® Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser!D: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> `If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): DAVE WINKLER Signature: <br /> Certification No.: 834975 License No: 5273934-UT 08-1740 OTTL <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2" STREET GALT,CA 95632 Date of Testing/Servicing: 10-22-2012 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> � � , <br />
The URL can be used to link to this page
Your browser does not support the video tag.