My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
236
>
2300 - Underground Storage Tank Program
>
PR0231333
>
COMPLIANCE INFO_1997-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2024 2:31:42 PM
Creation date
6/3/2020 9:46:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2012
RECORD_ID
PR0231333
PE
2361
FACILITY_ID
FA0003711
FACILITY_NAME
LAKEWOOD CHEVRON
STREET_NUMBER
236
Direction
N
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03710028
CURRENT_STATUS
01
SITE_LOCATION
236 N HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231333_236 N HAM_1997-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EVR/ISD SETUP <br /> EVR -TYPE: VACUUM ASSIST <br /> VACUUM ASSIST TYPE <br /> OUTPUT RELAY SETUP VACUUM <br /> VAC <br /> NOZZLE A/L RANGE <br /> R I :REG UNLEADED MAX: 1 .15 MIN: 0.95 <br /> TYPE: <br /> STANDARD VAPOR PROCESSOR TYPE <br /> NORMALLY CLOSED NONE <br /> TANK #: I <br /> ANALYSIS TIMES <br /> LIQUID SENSOR ALMS TIME: 11 :59 PM <br /> L J :FUEL ALARM DELAY MINUTES: I <br /> L 9:FUEL ALARM <br /> L10:FUEL ALARM ACCEPT HIGH ORVR: <br /> Lll :FUEL ALARM TANK 3 DISABLED <br /> L12:FUEL ALARM <br /> L I :SENSOR OUT ALARM ISD HOSE TABLE <br /> L 9:SENSOR OUT ALARM LIQUID SENSOR ALMS ID FP FL HL AA RR <br /> LIO:SENSOR OUT ALARM L. 3:FUEL ALARM <br /> Lll :SENSOR OUT ALARM L 9:FUEL ALARM 01 00 01 02 01 UU <br /> L12:SENSOR OUT ALARM LIO:FUEL ALARM 02 01 02 02 01 UU <br /> L I :SHORT ALARM Lll :FUEL ALARM 03 02 03 02 02 UU <br /> L 9:SHORT ALARM L12:FUEL ALARM 04 03 04 02 02 UU <br /> LIO:SHORT ALARM L 3:SENSOR OUT ALARM 05 04 05 02 03 UU <br /> Lll :SHORT ALARM L 9:SENSOR OUT ALARM 06 05 06 02 03 UU <br /> L12:SHORT ALARM L10:SENSOR OUT ALARM 07 06 07 02 04 UU <br /> Lll :SENSOR OUT ALARM 08 07 08 02 04 UU <br /> ISD SITE ALARMS L12:SENSOR OUT ALARM <br /> ISD GROSS PRES FAIL L 3:SHORT ALARM <br /> ISD DEGRD PRES FAIL L 9:SHORT ALARM ISD AIRFLOW METER MAP <br /> ISD VAPOR LEAK FAIL LIO:SHORT ALARM ID SERIAL NUM LABEL <br /> ISD SENSOR OUT WARN LlI :SHORT ALARM ------------------------- <br /> L12:SHORT ALARM 1 24220 DISP 1-2 <br /> ISD HOSE ALARMS 2 21773 DISP 3-4 <br /> ALL:GROSS COLLECT FAIL 3 21777 DISP 5-6 <br /> ALL:DEGRD COLLECT FAIL 4 22218 DISP 7-8 <br /> R 2:SUP UNLEADED <br /> TYPE: <br /> STANDARD ISD FUEL GRADE HOSE MAP <br /> NORMALLY CLOSED1 2 3 4 <br /> FP MHH MHH MHH MHH AA <br /> --------------------------- <br /> TANK #: 2 00 401 501 901 U U I <br /> SMARTSENSOR SETUP <br /> 01 402 502 902 U U I <br /> LIQUID SENSOR ALMS - - - - - - 7--- - - - - 03 404 02 403 5 503 903 U U 2 <br /> 04 904 U U 2 <br /> L 2:FUEL ALARM 04 405 505 905 U U 3 <br /> L 9:FUEL ALARM 1 :DISP 1-2 05 406 506 906 U U 3 <br /> L.10:FUEL ALARM CATEGORY AIR FLOW METER 06 407 507 907 0 U 4 <br /> Lll :FUEL ALARM 07 408 508 908 0 U 4 <br /> 1.12:FUEL ALARM s 2:DISP 3-4 <br /> L 2:SENSOR OUT ALARM CATEGORY AIR FLOW METER <br /> L 9:SENSOR OUT ALARM LABEL TABLE <br /> L10:SENSOR OUT ALARM - 3:DISP 5-6 --------------------------- <br /> Lll :SENSOR OUT ALARM CATEGORY AIR FLOW METER 1 : UNASSIGNED <br /> L12:SENSOR OUT ALARM 2: BLEND3 <br /> L 2:SHORT ALARM 4:DISP 7-8 3: REGULAR <br /> L 9:SHORT ALARM CATEGORY AIR FLOW METER 4: MID GRADE <br /> Llo:SHORT ALARM 5: PREMIUM <br /> L12:SHORT ALARM 5:P.S. 5-6 6: GOLD <br /> L12:SHORT ALARM CATEGORY VAPOR PRESSURE 7: BRONZE <br /> ISD SITE ALARMS 8: SILVER9: BLEND2 <br /> ISD GROSS PRES FAIL, 10: BLEND4 <br /> ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL <br /> ISD SENSOR OUT WARN <br /> ISD HOSE ALARMS <br /> ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL <br /> R 3:DIESEL <br /> TYPE: <br /> STANDARD PMC SETUP <br /> NORMALLY CLOSED <br /> PMC VERSION: 01 .02 <br /> VAPOR PROCESSOR TYPE <br /> NONE <br /> PROCESSOR CONTROL LEVEL: <br /> NONE <br />
The URL can be used to link to this page
Your browser does not support the video tag.