My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_1999-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 3:26:07 PM
Creation date
6/3/2020 9:46:53 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2009
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_1999-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. In -Trask Gauging I SIR Equipment: Chedi this box if tank gagging is used only for inventory control. <br />J heck this box if no tank gauging or Silt equipment is installed. <br />This section must be completed if in -tank gauging equipment is tised to perfonn.leak detection monitoring. <br />Q Yes Q No* I ties all input wiring bees inspected for proper entry and termination, including testing for ground faults? <br />0 Yea 10 No* I Were all tank gauging probes visually ' for damage and residue buildup? <br />❑ Yes ❑ No's I Was accuracy Of system product level readings tested? <br />❑ Yes D No's Was accuracy of system water level readings tested? <br />Yes Q No* Were all probes reinstalled properly? <br />la Yes 0 No* ik ere all items on the equipment manufacturer's maintenance checklist completed? <br />* Fu the Section H, beiosY, descxt'bc how and schen thmm defxcieades were or wM be corrected. <br />G. ]Line Leak Detectors (LLD)t 0 Check this box if LUDs are not installed. <br />complete the fW10 Ing checklist: <br />JYes :: No* For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br />❑ NIA (Check aU. that apply] Simulated leak rate: P 3 g:p1L; ❑. 0.I g p.h ; 010.2 g.p;h. <br />Yes ❑ No* Were all LLDs coafumed operational and accurate within regulatory requirements? <br />jk Yes <br />0 Nos' <br />Was the testing apparatus properly calibrated? <br />ca,Yes <br />0 No* <br />Q NIA <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />Li res U No" kw ciectroruc L.Lvs, does the turome automaucalty strut otfiftne LLU detects a 3eAkY <br />Q NIA <br />CI Yes 0 No* For electronic €.LDs, does the turbine automalitally shut off if any portion of the monitoring system is disabled <br />Q NM oc discvtmectrrd.? <br />0 Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunction. <br />0 NIA or fails a test? <br />Q Yes 0 No's For elecb= is LLDs. have all accessible wiring connections been visually inspected? <br />0 NFA . <br />cs ❑ No* W= all items on the equipment manufacturees maintenance checklist completed? <br />isa the Section H, betc►vc, desetihe how and wbren thrse d4dad cift wets or will be correctad_ <br />kI. Comments: <br />Page of 3 OYDI <br />
The URL can be used to link to this page
Your browser does not support the video tag.