My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 4:04:58 PM
Creation date
6/3/2020 9:46:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
353
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AQUf(y <br /> ?°' .rF '••G • SAN JOAQUIN COUNTY <br /> Z-► ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sogov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> vakoez' �� uo - 6 <br /> Facility Add res Sery a Request4&ww bi. L i , <br /> #: <br /> �4-1 <br /> Iq <br /> Onsite Servic' T h •cian's Name: ICC Service Te hnician/Installer Exp.Date: Manufacturer Training: <br /> SERVICE SERVICE <br /> Leak detector <br /> ❑ mechanical ModelSpill bucket El minimum 5 gallon <br /> El ❑ electronic Serial:: El 1 hour hydrostatic ❑ Incon TS-STS <br /> ❑ line test programmed <br /> ❑ Caldwell System El Other <br /> Leak detector <br /> ❑ mechanical ModelSpill bucket ❑ minimum 5 gallon <br /> El : El 1 hour hydrostatic ❑ Incon TS-STS <br /> El electronic Serial: <br /> ❑ ine test ro ramme ❑ Caldwell System El Other <br /> positive shutdown �od <br /> el: .��� Primary piping testing at: <br /> El fail safe Serial#: El psi <br /> El NA minutes <br /> sensor Secondary containment testing for: <br /> ❑ ❑ positive shutdown Model: UDC(s) Piping <br /> ❑ fail safe Serial#: Sump(s) UST(s) <br /> ❑ NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: <br /> ❑ fall safe Serial#: Note: Please be aware that 2°containment components are required to be tested upon <br /> ❑ NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention (see LG letter 150-1) Other: see below <br /> ❑ This UST facility is APPROVED to operate ❑ This UST facility is NOT APPROVED to operate <br /> Ate r i'v�rw b�p✓1 <br /> `U -P1 l <br /> C <br /> r Y r <br /> f1 a&z f" , tri N <br /> THIS F ILITY IS SU JECT EINSPECTION AT TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: k7--l' Received By: Title: <br /> EHD 23-04 �""1 UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 4/30/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.