IJNDERGRO MRAGE TANK <br /> SPONSE PLAN-PAGE 2 <br /> KEEPING <br /> FW'e will reportheeord any overfill.spill,or unauthorized release from a UST system as indicated in this plan. <br /> Rccord2ble Any unauthorvsd release from primary containment which the UST operator is able to clean up within eight(8)hours after the release was <br /> detected or should reasonably have been deteme d,and which does not escape from secondary containment,does not increase the hazard of fire or explosion,and docs <br /> not cause any deterioration of secondary containment,mustt be recorded in the facility's•monitoring records. Monitoring records must include: <br /> > The UST oporaWs nam and xlephone number, <br /> > A list ofthe types,quamtitics.and concerimnions of hamdous substances released; <br /> > A dewnption of the mons taken to control and clean up the release, <br /> > The method and bion of dispusat of the released hazardous sub9arteeas,and whether a hazardous waste mani€est was or will be used; <br /> A A description of actions taken to repair the UST and to prevent future releases. <br /> > A description of the method used to reactivate interstitial monitoring a€tor replacement or repair of primary containment <br /> Reportable • Any overfill,spill,or unauthori:wd release which escapes from secondary containment(or primary containment if no Secondary containment <br /> exists),increases the hazard of fire or explosion,or causes any deterioration of secondary containment,is a reportable release. Reportable releases are also recordable. <br /> Within 24 hours aper a reportable release has been detected,or should have been detected,we will notify the local agency administering the UST program of the <br /> release,' , ' the release,and take immediate measures to stop the release. If necessary,or if required by the local agency,remaining stored product/waste will <br /> be rumovod front the UST to prevent further releases or facilitate corrective action. if an emergency exists,we well notify the Statc Office of Emergency Services. <br /> Within five(5)working days of a reportable release,we will submit to the local agency a full writtexu report containing all of the following information to the anent <br /> that the information is known at the time of filing the report <br /> > The UST owner's or operdtot's name and telephone number, <br /> > A list ofthe typos,quantities,and concentrations of hazardous materials released; <br /> > The approximate date of the release, <br /> > The date on which the release was discovered; <br /> > The date on which the robe was stopped; <br /> > A deknpdon of actions taken to control and/or stop the release; <br /> > A description of corrective and remedial actions,including investigations which were undertaken and will be conducted to determine the nature and extern of <br /> soil,ground water or surface water contamination due to the release; <br /> > The method(s)ofeleanup implemented to date,proposed cleanup actions.and a schedule for implementing the proposed actions; <br /> > The method(s)and location(s)of disposal of released hazardous materials and any contaminated soils,rroundwate r,or surface water. <br /> > Copies ofany hazardous waste maiffests used for off-site transport ofhazardous wast;$associated with clean-up activity; <br /> > A description of proposed methods for any repair or replacement of UST system primary/secondary containment systems; <br /> > A description of additional actions taken to prevent future r classcs, <br /> We will follow the reporting procedures described above if any of the following conditions occur: <br /> > A recordable unauthorized rrdease can not be cleaned up or is still under investigation within eight(8)hours of detection; <br /> > Released hazardous substances are discover at the UST site or in the surrounding area; <br /> > Unusual operating conditions are observed,including erratic behavior of product dispensing equipment,sudden loss of product,or the unexplained presence of <br /> water in the tank,unless system equipment is found to be defective and is immediately repaired or replaced,and no leak has occurred; <br /> > Monitoring results from LIST system monitoring equipmenthncahods indicate that a release may have occurred,unless the monitoring equipment is found to be <br /> defective and is unme diatcly repaired,recalibrated,or replaced,and additional monitoring docs not confirm the initial mulls. <br /> Record Retention: Monitoring records and wd=n reports of unauthorized releases must be maintained on-site(or off-site at a readiJy available lotion,if approved <br /> by the local agency)for at least 3 years, Hazardous waste shipping/disposal records(e.g,manifests)must be maintained for at least 3 years from the date ofshipment. <br /> rWXFPR SIGNATURE <br /> CF:!12 JCA N- certify that the ioformAtion provided herein is truce andaccarate to the:best of my knowledge. <br /> O WOPBkASIG A DATE <br /> OWNER/ E TOR NAME(print) /�/�� Rpt' OWNEWOPf RATOR TF%E R <br /> V t/l Vt(/— <br /> (Agwrcy flee Only) This plarUms been reviewed and; Approved ❑Approved With Conditions t El Disapproved <br /> Local Agency Signature; Tuve: �c <br /> UN.=B-.3l3 www.unidoes org Rev.041IY M <br /> 9TO/ 900'd OOOZ# 90:t0 900Z/TZ/80 <br />