My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
1301
>
2300 - Underground Storage Tank Program
>
PR0231342
>
COMPLIANCE INFO_2010-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2021 4:04:58 PM
Creation date
6/3/2020 9:46:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2018
RECORD_ID
PR0231342
PE
2361
FACILITY_ID
FA0000392
FACILITY_NAME
FLAMES LIQUOR
STREET_NUMBER
1301
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95242
APN
03104030
CURRENT_STATUS
01
SITE_LOCATION
1301 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231342_1301 W KETTLEMAN_2010-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
353
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix <br />MONITORING SYSTEM CERTIFICATION RECEIVED <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of JUN <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system I <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General information <br />Facility FLAME LIQUOR CHEVRON Bldg. No.: <br />Site <br />AddfeCs• 1301 W KETTLEMAN LANE City: LODI CQ Zip: <br />Facility Contact <br />Parcnn• RUPI Contact Phone No.: ( ) <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 6/13/2011 <br />B. Inventory of Equipment Tested/Certified <br />Check the annronrlate bores. to indicata s.pacific equipment Inspected/serviced: <br />Tank ID: 87 <br />Tank ID: 91 <br />E In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />E In -Tank Gauging Probe. <br />Model: MAG 1 <br />E Annular Space or Vault Sensor. <br />Model: <br />420 <br />E Annular Space or Vault Sensor. <br />Model: 420 <br />E Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />E Piping Sump / Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />E Mechanical Line Leak Detector. <br />Model: <br />LD 2000 <br />E Mechanical Line Leak Detector. <br />Model: LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify .equipment type and model in Section E on Page 2). <br />ID: DSL <br />Tank ID: NA <br />liank <br />In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />%•',.❑ Annular Space or Vault Sensor. <br />Model: <br />SPLIT W 91 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />E Piping Sump / Trench Sensor(s). <br />Model: <br />208 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />E Mechanical Line Leak Detector. <br />Model: <br />FXIV - D <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 5-6 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />E Shear Valve(s). <br />E Shear Valve(s). <br />E Dispenser Containment Float(s) and <br />Chain(s). <br />E Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 3-4 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />E Shear Valve(s). <br />E Shear Valve(s). <br />E Dispenser Containment Float(s) and Chain(s). <br />E Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ ShearValve(s), <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />'if the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment Identified In this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this Information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ❑ System set-up ❑ Alarm history report <br />Technician Name (print): DAVE WINKLER Signature: <br />Certification No.: 5263373 -UT License No: 08-1739 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2 STREET GALT CA 95632 Date of Testing/Servicing: 6-13-11 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.