My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_1999-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 3:51:40 PM
Creation date
6/3/2020 9:47:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2005
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_1999-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
306
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> ` Ate' 3N?!i�P3TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE I O <br /> 1 L 3 h (two pages per tank) <br /> TYPE OF ACTION 111 NEW SITE PERMIT ❑ 4 AMENDED PERMIT (/ Page of <br /> ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check one item only) <br /> ❑ 7 PERMANENTLY CLOSED ON SITE, <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Specify reason-for local use only) ❑ 8 'TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: 1 <br /> USA GASOLINE#3 3 <br /> LOCATION WITHIN SITE(optional) <br /> 431 <br /> I.'TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> tADDITIONAL <br /> K ID# 43z TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes <br /> C6�y_6f�� ® No 434 <br /> ( 7 TRUSCO If"Yes".complete one page for each compartment. <br /> E INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS <br /> 437 <br /> 8 14000 <br /> DESCRIPTION(For local use only) <br /> 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE <br /> MOTOR VEHICLE FUEL ®la. REGULAR UNLEADEDtut <br /> ❑2. LEADED ❑5. JET FUEL <br /> (if marked complete Petroleum Type) ❑1 b. PREMIUM UNLEADED ❑3. DIESEL <br /> 06. AVIATION FUEL <br /> ❑2 NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER <br /> ❑3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials inventory page) 441 CAS#(front Hazardous Materials Inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL 0 3. SINGLE WALL WITif ❑5. SINGLE WALL WITH INTERNAL BLADDER SYS'ITM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER <br /> ❑95. UNKNOWN <br /> ®2. DOUBLE WALL [34. SIGNLE WALL IN VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank R9 1. BARE STEEL ❑3. FIBERGLASS/PLASTIC <br /> ❑5. CONCRETE [:195. UNKNOWN 444 <br /> (Check one item only) ❑2. STAINLESS STEEL [34. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL <br /> ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) <br /> TANK MA'T'ERIAL-secondary tank ❑ 1. BARE STEEL 3. FIBERGLASS/PLASTIC: ❑5. CONCRETE <br /> ❑95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ®4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPTIBLE W/100%METHANOL <br /> ❑99.OTHER <br /> REINFORCED PLASTIC(FRY) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING I.RUBBER LINED0 3.EPDXY LINING LJ 5.GLASS LINING 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED <br /> (Check one item only) ❑99 OTHER <br /> (For local use otdy) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ❑3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4 IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE <br /> (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ®1 SPILL CONTAINMENT 1998 <br /> ❑I AI-ARM ®3 FILL TUBE SHUT OFF VALVE <br /> ®2 DROP TUBE 1998 ❑2 BALL FLOAT <br /> ❑4 EXEMPT <br /> ®3 STRIKER PLATE 1998 <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 [F DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑1 VISUAL(EXPOSED PORTION ONLY <br /> ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL'TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(1/99 revised) Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.