MAR-21-2012 12:22 Service Station Systems 408 938 8888 P.03 <br /> Monitoring System Equipment Certification <br /> For Use lay All Jurisdictions Within The State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 13, California Code of Regulations <br /> This form must be used to document tasting and Servicing of monitoring equipment. A separate certification or renart must bg <br /> nmoared for each mtmiWring system control nand by the technician who performs the work. A copy of this form must be provided <br /> to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST system <br /> within 30 days of test date. <br /> A. General Information <br /> Facility Name: USA/Tesoro Bldg.No.: <br /> Site Address: 401 W. Kettleman Ln. City: Lodi,CA Zip: 95240 <br /> Facility Contact Person: Mike Contact Phone No.: (209)368-8787 <br /> Make/Model of Monitoring System: Gil EMC Date of Testing/Servicing: 2/23/12 <br /> % Inventory of Equipment Tested/Certified <br /> Cheek the appropriate boxes to indicate specific equipment inspected/serviced- <br /> Tank t!).01-Regu Tank 1Q,;!2_-Prom <br /> 13 in-Tank Gauging Probe. Model: VR 8473NA 07 E3 In-Tank Gauging Probe. Model: VR 1347390-107 <br /> ill Annular Space or Vault Sensor, Model: VR 794390+120 0 Annular Space or Vault Sensor. Model: VR 74!890.320 <br /> Cl piping Sump\Trench Sensor(s). Model: yR 794390499 M Piping Sump\Trench Sensor(s). Model: VR 793380-M <br /> p Fill Sump Sensor(s). Madel: p Fill Sump Sensor(s), Model: <br /> 0 Mechanical Lane Leak Detector. Model: RJ 115-9114-5 0 Mechanical Line Look Detector. Model: R31164583 <br /> p Electronic Line Leak Detector. Model: O Electronic Lina Leak Detector. Madel: <br /> p 'tank Overfill\High-Level Sensor. Model: ❑ Tank Overfill\High-Level Sensor. Model: _ <br /> ❑ Other(specify equipment type and model in Section E on Page 2). p Other(specify equipment type and model in Sonion E on Page 1). <br /> Tank l.DL rank 1D: <br /> ❑ in-Tank Gauging Probe. Model: ❑ In-Tank Gauging Probe. Model; <br /> ❑ Annular Space or Vault Sensor. Model: (3 Annular Space or vault Sensor. Model; <br /> [] Piping Sump\Trench Sensor(s). Model: ❑ Piping Sump\Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: p Fill Sump Sensor(s). Model: <br /> p Mechanical Line leak Detector. Madel: Q Mechanical Line Leak Detector, Model: <br /> Q illaurunic Line Imak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill\High-Level Sensor. Model: Q Tank Overfill\High-Level Sensur. Model: <br /> Q Other(specify equipment type and model in Section 11-on Page 2). 0 Other(specify equipment type and model in Section rs on Pago 2). <br /> Dispenser Ii); 01.02 Dispenser 1D• 03-04 <br /> p Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: <br /> a Shear Valve(s). Shear Valve(s). <br /> 151 Dispenser Containment Float(s)and Chain(s). 151 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 05-06 Dispenser 1% 07-08 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Model: <br /> ill Shear Valve(s). a Shear Valve(s). <br /> 9 Dispenser Containment Float(s)and Chain(s). a Dispenser Containment Float(s)and Chain(s). <br /> Dispenser tut Dispenser ID! <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispotiser Containment Sensor(s). Model: <br /> D Shear Valve(s). 0 Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispanscr Containmont Float(s)and Chain(s). <br /> "If the facility contains mora tanks or dispensers,copy this form.include information for every tank and dispenser at the facility <br /> C.Certification- T certify that the equipment identified in this dteument was inspected/serviced in accordance with the <br /> manufacturer's guidelines. Attached to this Certification is information(e g.m000factures'checklists)necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipment For any equipment capable of generating such <br /> reports,t have also attached a copy of the; (theca ort that tepply): 13 System set-up Q Alarm history report <br /> Technician Name(print):Steve Parmenter Signature: . '. <br /> Mfg.Cert.#.: A28780 1CC# 5311561-UT License.No.: 485184 <br /> Testing Company Name: Service Station Systems Phone No.: (488)971.2445 <br /> Testing Company Address: 680 Quinn Ave.,San Jose,CA 95112 Date of Testing/Servicing: 2/23/12 <br />