EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br />Selecting a Line Leak Detector <br />This guide helps you to properly configure Veeder-Root's line leak equipment for underground pressurized piping. Note: Fol- <br />lowing the industry's best practices, a containment sensor is recommended for sites with Pressurized Line Leak <br />Detection (DPLLD, PLLD or WPLLD) in the event that the submersible pump develops a leak before the check valve <br />and/or functional element. Line leak detectors only check leaks in the primary product line downstream from the pump. <br />Veeder-Root offers three types of line leak detectors, each uniquely suited to a particular type of application: <br />• DPLLD Digital Pressurized Line Leak Detection <br />• PLLD Pressurized Line Leak Detection <br />• WPLLD Wireless Pressurized Line Leak Detection <br />DPLLD, PLLD and WPLLD eliminate the need to break the product line for installation or service. In addition, WPLLD installs <br />without running new wires. DPLLD, PLLD and WPLLD are the cost-effective choice for most retrofit and new piping installations. <br />Veeder-Root's electronic line leak detectors have been evaluated by a third party in accordance with EPA evaluation proce- <br />dures. Please refer to the National Work Group Listings at www.nwglde.org. <br />FEATURE <br />SUPPORTED CONSOLE <br />DPLLD <br />(8590 Series) <br />PLLD <br />(8484 Series) <br />WPLLD <br />(8494 Series) <br />TLS-450PLUS <br />YES <br />NO <br />NO <br />TLS -450 <br />YES <br />NO <br />NO <br />TLS -350 <br />NO <br />YES <br />YES <br />LINE LEAK DETECTION <br />P15OUlY QS1 - QS3, AGP150SlY QS1 - QS3 (1-1/2 HP) YES <br />YES <br />X3P150U1Y QS1 - QS3, X3AGP150S1Y QS1 - QS3 (1-1/2 HP) YES <br />3 gph Testing <br />YES <br />YES <br />YES <br />Precision Testing <br />OPTIONAL <br />OPTIONAL <br />OPTIONAL' <br />Positive Shutdown <br />YES <br />YES <br />YES <br />3rd Party Certified <br />YES <br />YES <br />YES <br />INSTALLATION REQUIREMENTS <br />NO <br />Requires TLS Console <br />YES <br />YES <br />YES <br />Installs Without Breaking Piping <br />YES <br />YES <br />YES <br />Installs Without New Sump <br />YES <br />YES <br />YES <br />Installs Without New Wires <br />NO <br />NO <br />YES <br />I Not available for flexible piping <br />Line Leak Specifications - Supported Pump Models (Footnotes explained at end of table) <br />MODELS4-INCH FIXED SPEED <br />THE RED JACKET <br />P75U1RJ1 - RJ3, AGP75S1RJ1 - RJ3 (3/4 HP) <br />DPLLD/ <br />PLLD <br />YES <br />WPLLD <br />YES <br />P150U1RJ1 - RJ3, AGP150S1RJ1 - RJ3 (1-1/2 HP) YES <br />YES <br />X3P150U1RJ1 - RJ3, X3AGP150SiRJ1 - RJ3 (1-1/2 HP) YES <br />YES <br />P2000l-3RJ1 - RJ3, AGP200S1RJ1 - RJ3 (2 HP) YES <br />YES <br />RED JACKET <br />QUANTUM <br />P33U1 QS1 - QS3, AGP33S1 QS1 - QS3 (1/3 HP) <br />YES <br />YES <br />P75U1Y QS1 - QS3, AGP75S1Y QS1 - QS3 (3/4 HP) YES <br />YES <br />P15OUlY QS1 - QS3, AGP150SlY QS1 - QS3 (1-1/2 HP) YES <br />YES <br />X3P150U1Y QS1 - QS3, X3AGP150S1Y QS1 - QS3 (1-1/2 HP) YES <br />YES <br />X5P150U1Y QS1 - QS3, X5AGP150S1Y QS1 - QS3 (1-1/2 HP) NO <br />NO <br />P20001 -3Y QS1 - QS3, AGP200S1-3Y QS1 - QS3 (2 HP) YES <br />YES <br />STANDARD <br />P33R1 T1 - T4 (1/3 HP) <br />YES <br />YES <br />P75S1 T1 - T4 (3/4 HP) YES <br />YES <br />P150S1 T1 - T4 (1-1/2 HP) YES <br />YES <br />X3P150S1 T1 -T4 (1-1/2 HP) YES <br />YES <br />X5P150S1 T1 -T4 (1-1/2 HP) NO <br />NO <br />FE PETRO <br />STP33, STPAG33 (1/3 HP) <br />YES <br />YES <br />STP75, STPAG75 (3/4 HP) YES <br />YES <br />STP 150, STPAG150, STPAGH150 (1-1/2 HP) YES <br />YES <br />STP200, STPAG200, STPMR200, STPR200 (2 HP) YES <br />YES <br />STPH2O0, STPAGH2O0, STPHMR200, STPHR200 (2 HP) YES <br />YES <br />
The URL can be used to link to this page
Your browser does not support the video tag.