My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />E <br />4. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: F_] UDC Manufacturer 13 Industry Standard 0 Professional Engineer <br />0 Other (Speer) <br />Test Method Used: 1771 Pressure 0 Vacuum 0 Hydrostatic <br />El Other (Specify) <br />Test Equipment Used: Incon Sump <br />Tester Equipment Resolution: 0.002" <br />UDC # 1/2 UDC # 3/4 UDC # 5/6 UDC # 7/8 <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC Depth: <br />12" <br />12" <br />12" <br />12" <br />Height from UDC Bottom to Tap <br />of Highest Pi in Penetration: <br />Located on Bottom <br />of Pan <br />—T—ocated on Botton'i i <br />of Pan <br />Located on Bottom <br />I of Pan <br />Located on Bottom <br />of Pan <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Located on Bottom <br />of Pan <br />Located on Bottom <br />of Pan <br />Located on Bottom <br />of Pan <br />Located on Bottom <br />of Pan <br />Condition of UDC prior to <br />testing: <br />Good <br />Good <br />Good <br />Good <br />Portion of UDC Tested <br />2" above piping <br />2" above pipin� <br />2" above piping <br />2" above pipinga <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />0 Yes 0 No 0 NA <br />0 Yes 0 No 0 NA <br />OYes ONo ®NA <br />OYes ONo SNA <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />is system programmed for fail- <br />safe shutdown?* <br />E]yes oNo ®NA <br />0Yes 0No SNA <br />OYes oNo ®NA <br />[3 Yes E) No (D NA <br />Was fail-safe verified to be <br />operational?' <br />0Yes 0No SNA <br />0 Yes 0 No ED NA <br />0 Yes 0 No Z NA <br />- <br />171 Yes E] No 13 NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />8:35 am <br />8-35 am <br />10:04 am <br />10:04 am <br />Initial Reading (Rj): <br />4.0395 <br />1.4310 <br />1.4592 <br /># 1.9229 <br />Test End Time: <br />8:50 am <br />8:50 am <br />10:1.9 am <br />10:14 am <br />Final Reading (RF): <br />4.0391 <br />1.4307 <br />1.5003 <br />Test Duration: <br />15 min. <br />15 min. <br />15 min. <br />15 min, — <br />Change in Reading (RF-Rj): <br />0.0004 <br />0.0003 <br />0,0011 <br />0.0001 <br />PasslFail Threshold or Criteria: <br />+/-0.002" <br />0.002" <br />+/-0.002" <br />0.002" <br />Test Result: <br />[R] Pass 0 Fail <br />Pass 0 Fail <br />M Pass D Fail <br />[K Pass 0 Fail <br />Was sensor removed for testing? <br />0 Yes 0 No 0 NA <br />0 Yes D No 0 NA <br />[I Yes [I No ED NA <br />C] Yes [] No 0 NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 Yes <br />I <br />;0No®NA <br />— <br />E] Yes 0 No M NA <br />Comments — (include information on repairs made prior to testing, and recommendedollow-upfor fatted tests) <br />f <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.