My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak AppliAn Guide <br /> Selecting a Line Leak Detector <br /> This guide helps you to properly configure Veeder-Root's line leak equipment for underground pressurized piping. Note: Fol- <br /> lowing the industry's best practices,a containment sensor is recommended for sites with Pressurized Line Leak <br /> Detection(DPLLD,PLLD or WPLLD)in the event that the submersible pump develops a leak before the check valve <br /> and/or functional element.Line leak detectors only check leaks in the primary product line downstream from the pump. <br /> Veeder-Root offers three types of line leak detectors,each uniquely suited to a particular type of application: <br /> • DPLLD Digital Pressurized Line Leak Detection <br /> • PLLD Pressurized Line Leak Detection <br /> • WPLLD Wireless Pressurized Line Leak Detection <br /> DPLLD, PLLD and WPLLD eliminate the need to break the product line for installation or service. In addition,WPLLD installs <br /> without running new wires.DPLLD,PLLD and WPLLD are the cost-effective choice for most retrofit and new piping installations. <br /> Veeder-Root's electronic line leak detectors have been evaluated by a third party in accordance with EPA evaluation proce- <br /> dures. Please refer to the National Work Group Listings at www.nwglde.org. <br /> DPLLDFEATURE <br /> 1 (8590 Series) (8484 Series) (8494 Series) <br /> SUPPORTED CONSOLE <br /> TLS-450PLUS YES NO NO <br /> TLS-450 YES NO NO <br /> TLS-350 NO YES YES <br /> LINE LEAK DETECTION <br /> 3 gph Testing YES YES YES <br /> Precision Testing OPTIONAL OPTIONAL OPTIONAL' <br /> Positive Shutdown YES YES YES <br /> 3rd Party Certified YES YES YES <br /> INSTALLATION REQUIREMENTS <br /> Requires TLS Console YES YES YES <br /> Installs Without Breaking Piping YES YES YES <br /> Installs Without New Sump YES YES YES <br /> Installs Without New Wires NO NO YES <br /> t Not available for flexible piping <br /> Line Leak Specifications - Supported Pump Models (Footnotes explained at end of table) <br /> . . DPLLD/ <br /> 4-INCH FIXED SPEED PLLD WPLLD <br /> P75U1 RJ1-RJ3,AGP75S1 RJ1-RJ3(3/4 HP) YES YES <br /> P150U1RJ1-RJ3,AGP150S1RJ1-RJ3(1-1/2 HP) YES YES <br /> THE RED JACKET X3P150U1 RJ1-RJ3,X3AGP150S1 RJ1-RJ3(1-1/2 HP) YES YES <br /> P20001-3RJ1-RJ3,AGP200S1 RJ1-RJ3(2 HP) YES YES <br /> P33U1 QS1-QS3,AGP33S1 QS1-QS3(1/3 HP) YES YES <br /> P75UIY QS1-QS3,AGP75S1Y QS1-QS3(3/4 HP) YES I YES <br /> P150UlY QS1-QS3,AGP15OSlY QS1-QS3(1-1/2 HP) YES YES <br /> RED JACKET QUANTUM X3P150U1Y QS1-QS3,X3AGP150S1Y QS1-QS3(1-1/2 HP) YES YES <br /> X5P150U1Y QS1-QS3,X5AGP150S1 Y QS1-QS3(1-1/2 HP) NO NO <br /> P20001-3Y QS1-QS3,AGP200S1-3Y QS1-QS3(2 HP) YES YES <br /> P33R1 T1-T4(1/3 HP) YES YES <br /> P75S1 T1-T4(3/4 HP) YES YES <br /> STANDARD P150S1 T1-T4(1-1/2 HP) YES YES <br /> X3P150S1 Ti-T4(1-1/2 HP) YES YES <br /> X5P150S1 T1-T4(1-1/2 HP) NO NO <br /> STP33,STPAG33(1/3 HP) YES YES <br /> STP75,STPAG75(3/4 HP) YES YES <br /> FE PETRO STP150,STPAG150,STPAGH150(1-1/2 HP) YES YES <br /> STP200,STPAG200,STPMR200,STPR200(2 HP) YES YES <br /> STPH2O0,STPAGH2O0,STPHMR200,STPHR200(2 HP) YES YES <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.