My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
401
>
2300 - Underground Storage Tank Program
>
PR0231346
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/15/2023 4:05:16 PM
Creation date
6/3/2020 9:47:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231346
PE
2361
FACILITY_ID
FA0003603
FACILITY_NAME
TESORO (SPEEDWAY XP) 68152
STREET_NUMBER
401
Direction
W
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04513019
CURRENT_STATUS
01
SITE_LOCATION
401 W KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231346_401 W KETTLEMAN_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
620
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Applicion Guide 0 <br /> Supported Pipe Types and Line Lengths*- For DPLLD, PLLD and WPLLD (Continued) <br /> *lengths approved are for 3.0,0.2,&0.1 gph line leak tests using single pipe types.For mixed line types with DPLLD or PLLD,see footnote 1 and 6 respectively. <br /> FLEXIBLE PIPE -NUPRI (Continued) ► . . <br /> (Feet) (Feet) (Feet) (PSI) (Gallons/Foot) <br /> TSMAD-DOUBLE WALL <br /> 1.5 INCH 30-1100 30-1100 No 18900 0.092 <br /> 2 INCH 30-1100 30-650 No 12500 0.163 <br /> 3INCH 30-749 30-300 No 28200 0.367 <br /> TSMAXPD-DOUBLE WALL <br /> 1.5 INCH 30-1100 30-1100 No 15500 0.092 <br /> 2 INCH 30-1100 30-650 No 9200 0.163 <br /> 3INCH 30-749 30-300 No 27800 0.367 <br /> FLEXIBLE PIPE-PETROTECHNIK <br /> PETROTECHNIK UPP EXTRA(63 mm) 20-1100 20-650 No 11,500 0.163 <br /> FLEXIBLE PIPE -TOTAL CONTAINMENT <br /> ENVIROFLEX RETRACTABLE PIPE <br /> PP1500(1.5 INCH) 10-1100 10-1100 10-500 2400 0.092 <br /> PP1501(1.5 INCH) 10-1100 10-1100 10-500 3500 0.092 <br /> PP1502(1.5 INCH) 10-1100 10-1100 No 7300 0.092 <br /> PP1503(1.5 INCH) 10-1100 10-1100 No 2500 0.092 <br /> PP2500 AND PP2501(2.5 INCH) No No No — <br /> PP2502(2.5 INCH) 10-1078 10-430 No 8700 0.255 <br /> PP2503(2.5 INCH) 10-1078 10-430 No 3100 0.255 <br /> OMNIFLEX COAXIAL PIPE <br /> CP1501(1.5 INCH) 10-1100 10-1100 10-500 13,000 0.092 <br /> CP1503(1.5 INCH) 10-1100 10-1100 No 4500 0.092 <br /> CP2503(2.5 INCH) 10-1100 20-430 No 3900 0.255 <br /> 'Mixed Piping Types with PLLD: Using TLS-350 software Version 23 or later,PLLD is certified for 3 gph-only testing for line volumes up to 212 gallons;and for <br /> 0.2/0.1 gph testing for line volumes up to 110 gallons.To determine the line volume for mixed piping types,multiply the line length(in feet)times the'gal- <br /> Ions/foot'value for each pipe type and add the results.For example,site has 150 feet of 2"fiberglass and 50 feet of 3"fiberglass pipe: <br /> Total line volume= [150 x 0.204]+ [50 x 0.461]=30.6+23.1=53.7 gallons <br /> 2The 0.2 and 0.1 gph line leak tests cannot be run on flex piping with WPLLD. <br /> 313ulk Modulus entry is only applicable to TLS-350 consoles w/software Version 23 or later and all TLS-450 Series consoles.Refer to TLS-350 System Setup <br /> manual(P/N 576013-623)or TLS-450 Setup Manual(P/N 576013-940)for programming instructions. <br /> 46eoflex piping produced prior to 2001 has a lower bulk modulus than the current product.For this piping(pre-2001)use the values in().For 2001 piping and <br /> later, you must set the correct Bulk Modulus in the"User Defined"menu. <br /> 5Western Fiberglass COFLEX piping produced prior to 2005 has a different bulk modulus than the current product.For piping produced prior to 2005,use the <br /> values in(). <br /> 61-ine lengths shown represent DPLLD approved lengths for 0.2/0.1 gph testing.3.0 gph-only testing for DPLLD is certified for line volumes up to 535.6 gal- <br /> lons(not to exceed 1100 feet of line.See footnote 1 for instructions on calculating line volume for mixed piping. <br /> 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.