Laserfiche WebLink
Monitoring Procedures <br /> Underground Storage Tanks Monitoring Program <br /> fhi�program roust ax kept at the l's'r location at all times.The information on this monitoring program is conditions of the operating permit.The permit <br /> holder nw.t notili the County of San Qoaquin.Office of Emergency Services, Hazardous Materials Division(209.468.3969)within 30 days ofany <br /> change,to the numiUxing procedures,unless required to obtain approval before making changes. <br /> Required by section 2632(d)and 2641(h)CCR <br /> Facility Name: Paul Trehan Chevron <br /> Facility Address: 601 Kettleman Lane <br /> Lodi, California 95240 <br /> Monitoring Frequency: <br /> The monitoring frequency is to be continuous at the tank,tank sumps,fuel piping and dispenser sumps. <br /> ,Method.,and Equipment for monitoring: <br /> The proposed system is a VEEDER ROOT TLS-350. It is a continuous electronic monitoring system with discriminating <br /> sensors in the tank sumps.an interstitial tank sensor,and tank volume sensor.There is also a mechanical line leak detector <br /> :n each tank pump.The proposed mechanical leak detector is a FE-PETRO-MLD type capable of detection and shut doom <br /> 1'11nct ions. <br /> :Monitoring equipment locations: <br /> he monitoring control trill continuous read alarm and warning light fimctions is to be located in the store room of the <br /> existing facilit . Discriminating sensors are located in the tank sumps.There is an interstitial tank sensor in the new diesel <br /> lank.and tank volume sensors in all tanks. There is also a mechanical line leak detector at each tank pump. <br /> I itles and names of responsible individuals for monitoring and equipment maintenance: <br /> Mr. Paul Trehan(owner.operator)will be the lead person in this part of the Monitoring and maintenance program. <br /> Maintenance will be managed by. VEEDER ROOTas a part of the purchase agreement. <br /> :Monitor reporting format Tank: <br /> -Flicre is a continuous reporting format with a digital readout of current tank and line status. Hard copies can be printed upon <br /> demand. <br /> Preventative monitoring maintenance schedule: <br /> ,1s it part of VEEDER ROOT*s installation program a training session is included at the time off start-up. VEEDER ROOT <br /> Ntill prof ide an annual performance and maintenance visit and the facility manager will maintain a maintenance and reports <br /> log. <br /> Describe training program for operation of equipment: <br /> VEEDER ROOT has a start up training agreement as a part of their system and will train the facility manager and the <br /> facility manager will train selected subordinates. <br />