Laserfiche WebLink
AY 12 '97 12 : 15 FROM VEEDER-ROOT SERVICE TO 915104205890 PAGE . 002i008 <br /> Results of U.S. EPA Evaluation <br /> Automatic Tank Gaugingt (ATGS) <br /> Continuous Statistical Leak Detect Method (CSLD) <br /> This form tells whether the automatic tank gauging system (ATGS) described below used in <br /> a continuous statistical leak detect(CSLD)mode complies with the performance requirements <br /> of the federal underground storage tank regulation. The evaluation was conducted by the <br /> equipment manufacturer or a consultant to the manufacturer according to the 'Alternative <br /> Test Procedure Deemed Equivalent to EPA's." The full evaluation report also includes a form <br /> describing the method and a form summarizing the test data. <br /> Tank owners using this leak detection system should keep this form on file to prove <br /> compliance with the federal regulations. Tank owners should check with State and local <br /> agencies to make sure this form satisfies their requirements. <br /> ATGS Description <br /> Name TLS Series 300/400 onitorina SVStems with "LO <br /> .- <br /> Version Number 8472 Cagacii ncp, Prabe/8473 Maonetostrictive Probe <br /> Vendor Veeder Root <br /> 125 Powder F r Driv P.O. ox 2003 <br /> (street address) <br /> Simsbury Q T 0 70- 203 1- <br /> (city) (state) (zip) (phone) <br /> Evaluation Results <br /> This ATGS, which operates in two modes depending on the specified probability of detection <br /> of a leak rate of 0.20 gallon per hour, declares a tank to be leaking when the measured leak <br /> rate exceeds a threshold designed for the chosen mode. The threshold, probability of false <br /> alarm, P(FA), and probability of detection, P(D), of detecting a,leak rate of 0.20 gallon per <br /> hour, are given in the table below for the two modes of operation. <br /> Threshold Probability of False Alarm WA) Probability of Detection (P(D)l <br /> 0.17 <0.1% 95% <br /> 0.16 <0.1% 99% <br /> The minimum water level (threshold) in the tank that the ATGS can detect is 1.32 inches for <br /> the magnetostrictive version #8473 probe and 1.52 inches for the capacitance version#8472 <br /> probe. <br /> The minimum change in water level that can be detected by the ATGS iso 024 inch for the <br /> magnetostrictive version #8473 probe and Q Q27 inch for the capacitance version #8472 <br /> probe. <br /> Based on these results, the method 0 does 13 does not meet the federal performance <br /> standards established by the U.S. Environmental Protection Agency of 0.20 gallon per hour <br /> at P(D) of 95% and P(FA) of 5%. <br /> Test Conditions During Evaluation <br /> The data evaluation set included data from tanks of the following sizes <br /> Tank Size (gallons) < 51000 51000-91500 9,600- >20,000 Total # of <br /> 19,900 Records <br /> Number of Records 1 0 5 25 16 46 <br /> aw•1r+A P+Ct f1 RA,.s6a...d Dnw..1s.+ C.+�.—. ....Oman � AF Z <br />