My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 9:41:51 AM
Creation date
6/3/2020 9:47:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_2006-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si4ov.orq/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Kettleman Chevron Facility 601 E. Kettleman Ln. Lodi, CA Inspection Jul 24, 2013 <br /> Name: Address: Date: <br /> VIOLATIONS <br /> t999M Code Section HSC=CA Health and Safe Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (M1) <br /> CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M7) <br /> Other: I See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 105. UST Facility Operating Permit Application and UST Tank Information are not current in CERS. Any <br /> change of information must be updated in CERS within 30 days of the changes. Immediately log into <br /> CERS, update the required information, and submit for review by the EHD. Complete a separate tank <br /> form for each tank. <br /> 303. The 87 East turbine sump sensor was raised approximately 3 inches above the lowest point of the <br /> sump and the dispenser 9/10 sensor was raised approximately half an inch above the sump bottom. <br /> Neither sensor were located to detect a leak at the earliest opportunity. Monitoring equipment shall be <br /> maintained to be able to detect a leak at the earliest possible opportunity. During the inspection the <br /> technician repositioned the sensors to the lowest point of the sump to detect a leak at the earliest <br /> opportunity. <br /> 306. A fuel leak was found at the diesel filters in dispensers 3/4, 5/6, and 11/12. All primary containment <br /> must be product tight. Immediately have a properly licensed, trained, and certified contractor stop the <br /> leak. If the failed component can't be replaced immediately, there is a possibility that the diesel UST <br /> system may be red tagged to prevent fuel inputs. <br /> 310. Liquid was observed in the 87 west fill and turbine sumps, the 87 east fill sump, and the diesel <br /> turbine sump. If water could enter into the secondary containment by precipitation or infiltration, it must <br /> be removed and disposed of properly. Immediately remove this liquid, make a hazardous waste <br /> determination per Title 22 hazardous waste regulations, and manage it accordingly. Ensure that the <br /> secondary containment sumps are maintained free of liquid. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by August 24, 2013. <br /> Ensure that all required information has been entered into the online California Electronic Reporting <br /> System. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector: Received By: �\ � Title: <br /> EHD 23-02 Rev 04/19/12 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.