My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 9:41:51 AM
Creation date
6/3/2020 9:47:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_2006-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EW <br />Intelligent Submersible Turbine Pump Specifications <br />B <br />A <br />For full diagram see page 5. <br />Power Requirements <br />IST models can only be powered by a <br />MagVFC- controller: <br />• 2 hp models can operate with single- or <br />three-phase incoming power supply to <br />the MagVFC-. <br />• 4 hp models require three-phase incoming <br />power supply to the MagVFC- for <br />proper operation. <br />• Incoming power supply to the MagVFC- <br />can be 200-250 VAC, 50 or 60 Hz. <br />• MagVFC'" outputs a three-phase, variable <br />frequency signal, valid for FE Petro variable <br />speed pumps only. <br />• 2 hp max. motor draw: 9 Amps. <br />• 4 hp max. motor draw: 15 Amps. <br />• MagVFC- max. line draw: 20 Amps. <br />Pump Motor <br />• 2 hp or 4 hp, variable speed, two-stage <br />centrifugal type pump motor with integral, <br />automatic, thermal overload protection. <br />• Max. flow: 2 hp = 110 gpm, 4 hp = 140 gpm. <br />• Max. pressure: selectable operating <br />pressure on MagVFC- between 24 psi and <br />42 psi deadhead. <br />• Available with MagShell-, which results in <br />45% increased flow area around motor. <br />Liquid Compatibility <br />• Max. liquid viscosity: 70 SSU at <br />60 °F (15 °C). <br />• IST models imply alcohol -gasoline <br />compatibility for fuel mixtures containing <br />up to 100% ethanol or methanol, and <br />20% MTBE, 20% ETBE or 17% TAME <br />with gasoline. <br />• IST models can also be used with diesel <br />fuels, fuel oils, kerosene, Avgas and jet fuels <br />in a non -gelled pourable state. <br />• All wetted elastomers are made of a high <br />grade, fluorocarbon Viton' compound. <br />Standard Features <br />• All IST models include variable <br />speed, variable length options and <br />alcohol -gasoline compatibility. <br />• Check valve: 2'/+" diameter fluorocarbon <br />body and steel backing washer. <br />• Pressure relief valve: available in four <br />pressure relief settings, integral to check <br />valve. Standard model relieves at 40 psi and <br />resets above 35 psi. <br />• Syphon: venturi-type syphon primer <br />supplied with every submersible. Syphon <br />check valve and secondary syphon sold <br />separately. <br />• Air eliminator: every submersible includes <br />tank return path with one-way check valve <br />to provide active air elimination. <br />• Electrical disconnect: electrical yoke <br />for positive contractor disconnect <br />during service. <br />Approvals <br />• Consult factory for applicable approvals. <br />Quality Certification <br />• Franklin Fueling Systems is an ISO 9001 <br />Certified Manufacturer. <br />`Viton® is a registered trademark of DuPont <br />Dow Elastomers. <br />Qm� <br />f <br />F7 <br />typicalturbine model designation <br />as up to five components to define <br />he pump being supplied as follows:' <br />= Basic Model Designation <br />lote: All IST models include <br />rhd tir nc'nf alrnhnl-Gasoline <br />variable length as part of the <br />base model. <br />Options <br />IST model designations may include <br />one or more of the following; <br />characters in alphabetical order: <br />female adapter) <br />K = Intake filter screen(IFS factory <br />installed to PMA) <br />M = MagShell'° (flow enhancing, <br />expanded PMA shell) <br />R" = Model R check valve: (24 psi <br />relief/22 psi reset for PLLD) <br />W' Madel,W check valve (16 psi <br />relief/ 13 psi reset for PPM4000) <br />'Note: If'not otherwise specified, all IST <br />models are supplied with <br />standard model check valve (40 <br />psi relief/35 psi reset for MLD <br />and TS-LS300). <br />= Pump Motor Horsepower <br />Rating**; <br />VS4 = 4 hp variable speed <br />-Note: If not otherwise specified, 2 hp <br />variable speed is implied. <br />Model Length <br />I = 2 hp variable length, 59"-87" <br />2 = 2 hp variable length, 90"-151 <br />3 = 2 hp variable length, 122"-213 <br />VLI = 4 h variable length 64!,92" <br />4 hp variab <br />
The URL can be used to link to this page
Your browser does not support the video tag.