Laserfiche WebLink
SWRCB, January 2002 Page of <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: <br />❑ UDC Manufacturer <br />❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: <br />❑ Pressure <br />❑ Vacuum <br />X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Equipment Resolution: <br />.002 <br />UDC # i&2 <br />UDC # 3&4 <br />UDC # 5&6 <br />UDC # 7&8 <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />Fiberglass <br />UDC Depth: <br />28" <br />28" <br />28" <br />28" <br />Height from UDC Bottom to Top <br />11" <br />10" <br />10" <br />10" <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />6" <br />5" <br />6" <br />5" <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Dry <br />Dry <br />Dry <br />Dry <br />testing: <br />Portion of UDC Tested <br />Water Line 14" <br />Water Line 14" <br />Water Line 14" <br />Water Line 14" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />X Yes No ❑ NA <br />X Yes No ❑ NA <br />X Yes No ❑ NA <br />X Yes No ❑ NA <br />product and water)?* <br />Turbine shutdown response time <br />Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail- <br />X Yes ❑ No ❑ NA <br />X Yes []No ❑NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No [INA <br />safe shutdown?` <br />Was fail-safe verified to be <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />Yes X No ❑ NA <br />operational?* <br />Wait time between applying <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />water and starting test <br />Test Start Time: <br />10:50 <br />10:55 <br />11:00 <br />11:05 <br />Initial Reading Rl): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />11:20 <br />11:25 <br />11:30 <br />11:35 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading RF -RI :dand <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Crite.005/30 <br />Minutes <br />.005/30 Minutes <br />.005/30Minutes <br />.005/30 Minutes <br />Test Itesatt: <br />X' aswsF <br />X' Pass 0 Fain <br />X Piss 0 Fail <br />'X Pass' 0 Fait <br />Was sensor removed for testX <br />Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No [INA <br />Was sensor properly replaceXYes <br />❑No ❑NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />verified functional after testi <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to as of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />