Laserfiche WebLink
D. Results of Testing/Servici <br />Software Version Installed: <br />. r <br />Complete the;followng checklist: <br />s <br />❑ No* <br />Is the audible alarm operational? <br />Is the visual alarm operational? <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Were all sensors installed at lowf st point of secondary containment and positioned so that other equipment will <br />not interfere with their proper operation? <br />Yes <br />❑ No* <br />❑ No* <br />❑ No* <br />Yes <br />Cl Yes <br />❑ No* <br />_ <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />operational? <br />es <br />❑ No* <br />❑ N/A <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ump/Trench Sensors; E"Yispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? Rlres; ❑ No. <br />For tank systems that utilize the monitoring system as the primary tank, overfill warning device (i.e. no <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? % <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />Cl Yes <br />❑ No* <br />/A <br />No <br />El Yes* <br />ElYes* <br />No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that appl}J <br />❑ Product; ❑ Water. If yes, describe causes. in Section E, below. <br />Was monitoring system set-up reviewed to ensure proper settings? Attach setup reports, if applicable <br />s <br />El No* <br />Yes <br />❑ No* I <br />Is all monitoring equipment operational per manufacturer's specifications? if <br />* In Section E DOW, <br />E. Comments: <br />