Laserfiche WebLink
Ak Milk <br /> qw <br /> San Joaquin County qw <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.oW ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> KETTLEMAN CHEVRON 601 E KETTLEMAN LN LODI July 22 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions. <br /> Maintenance and monitoring records for the last three years were not found on site. The 2-17-15 designated operator <br /> report did not have a maintenance receipt to address the Q2 87(2) shut down alarm on 2-16-15 nor for the T1 91 ATG <br /> probe out alarm on 8-15-14. Also, the designated operator and facility personnel did not document these alarms. <br /> These records shall be maintained on site for at least three years. Monitoring records include: (1) date and time of all <br /> monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any visual <br /> observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other <br /> monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br /> reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br /> site and submit copies to the EHD. <br /> This is a repeat violation, Class II. <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to check and note the correct test dates for the secondary containment tests on the <br /> 7-8-15, 6-19-15, 5-15-15, 4-17-15, 3-27-15, 2-17-15, and 1-27-15 designated operator monthly inspection reports. On <br /> the 7-8-15 and 6-19-15 designated operator reports, the designated operator listed the secondary containment test as <br /> 1-20-15. On the 5-15-15, 4-17-15, 3-27-15, 2-17-15, and 1-27-15 designated operator monthly inspection reports, the <br /> designated operator listed the secondary containment test as 1-2-15. This test date should have been listed as <br /> 1-28-15. During the monthly inspection, the designated operator shall check that all required testing and maintenance <br /> for the UST system have been completed and document the dates they were done. Ensure that designated operators <br /> performing monthly inspections at this facility are including all of the required information on the reports. <br /> The 2-17-15 designated operator report did not have a maintenance receipt to address the Q2 87(2) shut down alarm <br /> on 2-16-15 nor for the T1 91 ATG probe out alarm on 8-15-14. Also, the designated operator and facility personnel did <br /> not document these alarms. The designated operator failed to document all the alarms from the attached alarm history <br /> on the 2-17-15 and 9-17-14 designated operator monthly inspection reports and failed to check that they were <br /> responded to appropriately. During the monthly inspection, the designated operator shall review the alarm history for <br /> the previous month, check that each alarm was documented and responded to appropriately, and attach a copy of the <br /> alarm history with documentation taken in response to any alarms to the monthly report. Ensure that designated <br /> operators performing monthly inspections at this facility are including all of the required information on the reports. <br /> This is a repeat violation, Class Il. <br /> 326 CCR 2635(b)(2)Overfill prevention system not present, was overridden, or failed to meet overfill requirements. <br /> The external visual alarm used as part of the overfill prevention system is not currently functional on the diesel UST. <br /> The external visual alarm was replaced by the business owner Harvinder Singh and retested by Afford-a-Test during <br /> the inspection. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Received by Inspector: Phone: Date: <br /> (initial): ARTS VELOSO, Senior REHS (209)468-3453 07/22/2015 <br /> Page 4 of 5 <br />