My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
601
>
2300 - Underground Storage Tank Program
>
PR0231348
>
COMPLIANCE INFO_2006-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 9:41:51 AM
Creation date
6/3/2020 9:47:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2015
RECORD_ID
PR0231348
PE
2361
FACILITY_ID
FA0003803
FACILITY_NAME
KETTLEMAN CHEVRON
STREET_NUMBER
601
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04728006
CURRENT_STATUS
01
SITE_LOCATION
601 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231348_601 E KETTLEMAN_2006-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
534
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�i <br /> UNIFIED PROGRAM CONSOLIDATED FORM 16 )j i7 <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(one form per UsT) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,UI,N,and IX below) 430 <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: "i <br /> DATE EXISTING UST DISCOVERED: 43M <br /> I. FACHATY INFORMATION <br /> FACILITY ID#(agency Use Only) <br /> 19 S <br /> BUSINESS NAME Same as FACILITY NAME or DBA-Doing Busin As) s <br /> v�� <br /> BUSINE SITE ADSS m � f, 103 CICY / sa4 <br /> II.TANK DESCRIPTION <br /> TANK ID# p p 432 TANK MANUFACTURER 433 TANK CONFIGURATION:THIS TANK IS 434 <br /> A STAND-ALONE TANK <br /> J� 2.ONE IN A COMPARTMENTED UNIT. <br /> Ide owe Me for each compartnmm is We unit <br /> DATE UST SYSTEM INS ALLED 435 TANK _ ALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> i� bon ) <br /> USE AND CONTENTS <br /> TANK USEla.MOTOR VEHICLE FUELING ❑ ib.MARINA FUELING ❑ 1c.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.IIAT..ARDOUS WASTE(lwclW s UsedOi) ❑ 5.EMERGENCY GENERATOR FUEL[HSC¢3281.5(c)) <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHERS <br /> OTHER(Specify): 439a <br /> CONTENTS PETROLEUM: ❑ la.REGULAR UNLEADED ❑ lc.MIDGRADE UNLEADED lb.PREMIUM UNLEADEV 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (specify): 440a <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ I I.OTHER NON-PETROLEUM(specify): 440b <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL %Z.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ L STEEL V&3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL .FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑99.OTHER(Specify): 445a <br /> OVERFILL PREVENTION 1.AUDIBLE.&VISUAL ALARMS ❑ 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 45L <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.S`lNGLE-WALLED W.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ba 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION 73 CCR§2636(ax3)) 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL 1&4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGIDPLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTIER(Specify): 464a <br /> SECONDARY CONTAINMENT 01, <br /> 1.STEEL 1&4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ❑ 1.SINGLE WALL tv 2.DOUBLE WALL ❑ 90.NONE 4644 <br /> VL VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT M 1.STEEL 0 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464el <br /> VENT SECONDARY CONTAINMENT V 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464E <br /> 464fl <br /> VR PRIMARY CONTAINMENT 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 464 i <br /> VR SECONDARY CONTAINMENT is 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464h <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL 2.DOUBLE WALL ❑ 90.NONE 4641 <br /> RISER PRIMARY CONTAINMENT i.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464j <br /> 464if <br /> RISER SECONDARY CONTAINMENT 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99-OTHER(Specify) 464k <br /> kt <br /> 64 <br /> FILL COMPONENTS INSTALLED I.SPILL BUCKET ❑ 3.STRIKER PLATEIBOTTOM PROTECTOR ❑ 4.CONTAINMENT SUMP 4 464 l <br /> VII.UNDER DISPENSER CONTAINMENT"C} <br /> CONSTRUCTION TYPE ❑ 1.SINGLE WALL (92.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) rea _.xr 469bc <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION 10 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system is compatible with the hazardous substance stored and that the information provided herein" to ie,accurate, <br /> and in full compliance w'th legal requirements. <br /> APPLICANT SIGNATURE DATE D ` l 470. <br /> APPLICANT NAME(print) a7s. APPLICANTTITLE 47_ <br /> �o `r � ���r}. �� d� m y <br /> UPCF UST-B-112 Rev.(12/2007) <br />
The URL can be used to link to this page
Your browser does not support the video tag.