My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_1996-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 2:27:51 PM
Creation date
6/3/2020 9:47:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2005
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_1996-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
424
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a cF O\ \� <br /> FIED PROGRAM CONSOLIDATED FORK, a\ TA, : TA050 52 <br /> b� <br /> PR#: PR0231350 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 I FAC#: FA0003690 <br /> two pages per tank) <br /> Page 4 of 7 //� <br /> TYPE OF ACTION ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT FA5 CHANGE OF NFOR.MATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Check only item only) - i• 3 } rte. ?- ❑ 7 PERM,3,NENTLY CLOSED ON SITE <br /> ;,.(Spmfyttuontorkuatttsetmty) (Specs torlonitaeoQlY) ❑ 8TANK REMOVED 430 <br /> ❑ <br /> 3 RENEWAL PERMIT <br /> BUSINESSNA:ME(SameasFACILITYNAMEorDBA-Doing Business M) FACILITY ID: PR#: I <br /> LODI FOOD&LIQUOR* ; FA0003690 PR0231350 FM I <br /> LOCATION WITHIN SITE(Optional) 1225 W LOCKEFORD ST,LODI 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 5 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑ Yes ❑ No 434 <br /> TA0506252 MODERN WELDING 1f"Yes',complete ompage for each comparrncnt. <br /> DATE INSTALLED(YEA=:d <br /> TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 10 000 <br /> ADDITIONAL DESCRIPTION(For local use only) 433 <br /> II.TANK CONTENTS <br /> TANK USE179 PETROLEUM TYPE 440 <br /> ® I.MOTOR VEHICLE FUEL ® la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (If marked complete Pcuolcum Type) ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAME(from Hazardous Materials Inventory page) 447us rdoMaterials Inventory page) 341 <br /> ❑ 4.HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> 111.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ L SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER - <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ® STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100?'.METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ I.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100°'o METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> 447 <br /> TANK INTERIOR LINING ❑ I.RUBBER LINED ❑ 3.EPDXY LINING ❑ 5.GLASS LINING ®95.UXKNOW-N 446 DATE INSTALLED <br /> OR COATING <br /> ❑ 99.OTHER <br /> (Cheek one item only) ❑ 2 ALKYD LINING E] ❑4 PHENOLIC LINING 6 UNLNED (For local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ® 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 449 DATE INSTALLED , 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> ❑4 IMPRESSED CURRENT ❑ 99 OTHER <br /> (Check one item only) ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR NSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply)PF y) SPILL CONTAINMENT 1,996.00 . - 1 ALARM 3 FILL TUBE SHUT OFF VAL' <br /> - ❑ <br /> DROPTUBE ❑ 2BALL ❑ 4EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one it-only) <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑ 4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑ 3 M.ALNUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑99 OTHER <br /> V.TANK CLOSURE L\FOR,NIATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page