Laserfiche WebLink
PRASURE-VACUUM VD& <br />548 & 548A 748 & 748 A <br />PRESSURE -VACUUM <br />77:PRESSURE-VACUUM <br />VENT VENT <br />WITH GAUGE HATCH <br />For "normal" venting of Aboveground Stor- For "normal" venting of Aboveground Stor- <br />age Tanks. Allows tank to "breath" duringInsh` age Tanks. Allows tank to "breath" during <br />filling and withdrawing operations. Pressure - <br />filling and withdrawing operations. Pressure <br />.4 vacuumpoppetssealvaporsinthetankwhen vacuum poppets seal vaporsinthetankwhen <br />pressure is equalized. This vent must be pressure is equalized. This vent must be <br />FIG 548 used in conjunction with an emergency vent FIG 748 used in conjuction with an emergency vent <br />and it is RECOMMENDED that the opening and it is RECOMMENDED that the opening <br />pressure setting is set below that of the emer- pressure setting is set below that of the emer- <br />gency vent so the normal vent relieves first. gency vent so the normal vent relieves first. <br />CONSTRUCTION DETAILS CONSTRUCTION DETAILS <br />FIG 548...................Brass Body and Hood. FIG 748 .................. .Stainless Steel Poppets. <br />FIG 548 A................Aluminum Body and Hood. FIG 748 A ............... Brass Poppets <br />(Fig 748 available in 2.0 oz/ sq in pressure - 1.0 oz/ sq in Vacuum only) <br />Standard Features: <br />1. Brass (raised) metal -to -metal Seats/Poppets. Standard Features: <br />2. Threaded Gauge Hatch for manual gauging access. 1. Aluminum Body and Hood. <br />3. Horizontal Discharge and field -adjustable, tripolar orientation. 2. Horizontal Discharge with field -adjustable tripolar orientation. <br />Size Pressure Vacuum Fig 548 Fig 548A Venting Size Pressure Vacuum Fig 748 Fig 748A Venting <br />Setting Setting Ship Ship Capacity Setting Setting Ship Ship Capacity <br />(oz /sq in) (oz /sq in) Weight Weight (CFH) (oz /sq in) (oz /sq in) Weight Weight (CFH) <br />(LBS) (LBS) (@2.5 PSI) (LBS) (LBS) (@2.5 PSI) <br />2" 2.0 1.0 13.25 7.00 20,200 2" 2.0 1.0 13.25 7.00 20,200 <br />2" 4.0 1.0 13.75 8.75 20,200 2" 4.0 1.0 NA 8.75 20,200 <br />2" 6.0 1.0 14.25 8.50 20,200 2" 6.0 1.0 NA 8.50 20,200 <br />2" 8.0 1.0 14.75 9.50 20,200 2" 8.0 1.0 NA 9.50 20,200 <br />2" 12.0 1.0 15.75 10.50 18,600 2" 12.0 1.0 NA 10.50 18.600 <br />2" 16.0 1.0 17.00 11.25 18,000 2" 16.0 1.0 NA 11.25 18,000 <br />3" 2.0 1.0 26.25 12.25 43,000 <br />3" 4.0 1.0 27.25 13.75 43,000 <br />3" 6.0 1.0 28.25 15.00 43,000 <br />3" 8.0 1.0 28.75 15.75 43,000 <br />3" 12.0 1.0 29.25 15.75 40,000 <br />3" 16.0 1.0 33.25 20.50 40,000 <br />FIG 749 <br />CONSTRUCTION DETAILS <br />FIG 749 - 2" NPT <br />FIG 749 S - 2" Slip-on style <br />FIG 749 CRB - 2" NPT <br />C.A.R.B. approval (95-15A) <br />for Stage I and ll. Viton 0 -rings <br />on pressure poppet. <br />Body ..................... Aluminum <br />Pressure Poppet... Aluminum <br />Vacuum Poppet.......... Brass <br />Seal........................... Buna-N <br />Screen ........................... Brass <br />749 SERIES <br />PRESSURE -VACUUM <br />VENT <br />Vent valve used on underground & low <br />volume aboveground tanks for motor <br />fueling. Vent allows tank to "breath" <br />during filling/dispensing operations. <br />Poppets seal vapors in the tank when <br />pressure is equalized. Settings are <br />approximate. <br />Warning: FIG 749 PN Vent must only <br />be used in conjunction with motor <br />fueling and/or low capacity flow. Fluid <br />handling in lines larger than that used <br />for retail service station can cause <br />tank to rupture or implode. <br />Pressure Vacuum Ship Venting <br />Setting Setting Weight Capacity <br />(oz /sq in) (oz /sq in) (LBS) (CFH) <br />(@2.5 PSI) <br />FIG 749 & 749 S <br />8.0 0.5 1.0 8,500 <br />12.0 0.5 1.0 8,500 <br />FIG 749 CRIB <br />3"W.C. 8" W.C. 1.2 <br />8 oz. 5 oz. 1.2 <br />WARNING: Obstruction of airflow through vents can <br />result in structural deformation of the tank. Atmo- <br />spheric conditions and below freezing temperatures <br />may cause condensation to occur and freeze. Freezing <br />action can restrict movement of poppets and block <br />screened air passages. Monthly inspection and more <br />frequent inspection in cold weather by someone famil- <br />iar with the proper operation of this vent is required to <br />help guard against accidental damage to the tank. For <br />further instructions contact: Morrison Bros. Co. <br />Dubuque Iowa (319) 583-5701. <br />CONSTRUCTION DETAILS <br />Size....................................2" NPT <br />Body and Cap...............Aluminum <br />Poppets ......... Teflon Coated Alum <br />Screens ................. Stainless Steel <br />Option: (Must specify) - male <br />NPT connection for dryer appli- <br />cation. <br />748 ALT <br />PRESSURE -VACUUM <br />VENT <br />FOR AG -CHEMICAL <br />Vent valve used with aqua-amonia and <br />ag-chemical products allowing tank to <br />"breathe" during loading/unloading op- <br />erations. Poppets seal vapors in the <br />tank when pressure is equalized. Set- <br />tings are approximate. <br />Pressure Vacuum Ship Venting <br />Setting Setting Weight Capacity <br />(Ibs /sq in)(oz /sq in) (LBS) (CFH) <br />(@2.5 PSI) <br />0.5 1.0 5.5 20,200 <br />1.0 1.0 5.5 18,000 <br />2.0 1.0 6.0 NA <br />25 <br />