My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOCKEFORD
>
1225
>
2300 - Underground Storage Tank Program
>
PR0231350
>
COMPLIANCE INFO_1996-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2023 2:27:51 PM
Creation date
6/3/2020 9:47:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2005
RECORD_ID
PR0231350
PE
2361
FACILITY_ID
FA0003690
FACILITY_NAME
LODI FOOD & LIQUOR*
STREET_NUMBER
1225
Direction
W
STREET_NAME
LOCKEFORD
STREET_TYPE
ST
City
LODI
Zip
95240
APN
03710002
CURRENT_STATUS
01
SITE_LOCATION
1225 W LOCKEFORD ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231350_1225 W LOCKEFORD_1996-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
424
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 Trenching' bedding <br />RECOMMENDED PRACTICES <br />and backfilling <br />Although fiberglass pipe has excellent strength, it must be protected against impact <br />which may occur from improper handling or during backfilling. <br />• Provide a trench width equal to the pipe diameter plus six inches on each side. <br />Separate multiple lines by at least 4 inches. Refer to Fig. 5-1. <br />• Provide a minimum of 18 inches of select backfill between the top of the pipe <br />►' <br />and unpaved ground surfaces. <br />• Provide a minimum of 4 inches of select backfill between the top of the pipe and <br />reinforced concrete pavement (4 inches minimum thickness). <br />• Provide a minimum of 8 inches of select backfill between the top of the pipe and <br />^.� <br />asphalt pavement (2 inches minimum thickness). <br />y• <br />Slope the trench bottom evenly from the dispensers back to sumps or tanks at a <br />RECDEIVED <br />minimum's in/ft. <br />JUL1 1 <br />• Maintain the trench bottom free of hard or sharp objects. <br />• Grade the trench bottom with at least 6 inches of select backfill to provide firm, <br />ENVIRONMENTAL HEALTH <br />even support for the pipe. Compact the subgrade well to prevent differential <br />PERMIT / SERVICES <br />settling. <br />• Protect the pipe from impact during backfilling and abrasion during operation by <br />surrounding it with four to six inches of select backfill such as washed sand, pea <br />gravel (3/4-inch maximum) or crushed stone (1h-inch maximum).' <br />• Wrap pipe lying near concrete with rubber or foam padding to avoid direct <br />contact with the concrete. <br />IF""" <br />Fig. 5-1. Use only select materials <br />for bedding and backfilling <br />Dualoy 3000/L fuel handling <br />systems. Native materials <br />are rarely suitable and <br />should not be used. <br />6 Dry fitting contained <br />primary piping <br />(i <br />Fig. 6-1. During layout, bonding <br />and inspection, support the piping <br />on 2x4 blocks to keep the joints <br />clean and to keep bedding <br />out of the pipe. <br />None <br />Asphalt 2 (min) <br />Concrete <br />4 (min) 18 (min) <br />o ,zl, o .� <br />8 (min) <br />4 (min) O O O <br />6 (min) <br />Native — ---- <br />soil%/����«i — -- <br />Select backfill <br />4 (min) 6 (min) <br />RECOMMENDED PRACTICES <br />• Have island forms, boxes, and shear valves in place before dry fitting. <br />• Lay out and dry fit primary and containment piping at the same time. <br />• Allow sufficient clearance when dry fitting the primary to accommodate the <br />-- containment fittings. <br />Dimensions of containment <br />fittings may be found at the end <br />of this document. <br />3 <br />
The URL can be used to link to this page