Laserfiche WebLink
San Joaquin t DIRECTOR <br /> ca U e N Donna Heran,REHS <br /> ®PEnvironmental Health Department <br /> ..._ c90 ASSISTANT DIRECTOR <br /> 600 East Main Street Laurie Cotulla,REHS <br /> :{ Stockton, California 95202-3029PROGRAM COORDINATORS <br /> • Carl Borgman, REHS <br /> Mike Huggins, REHS, RDI <br /> qL�F®R�� <br /> Website: SjoV.OP /eh Margaret Lagorio,REHS <br /> Phone: (209)468-3420 Robert McClellon,REHS <br /> Fax: (209) 464-0138 Jeff Carruesco, REHS, RDI <br /> Kasey Foley, REHS <br /> December 11, 2008 <br /> Ken Wendt <br /> Wendt& Sons Construction,Inc. <br /> P.O. Box 1403 <br /> Lodi, CA 95240 <br /> Fax: (209)547-9312 <br /> RE: Lodi Food&Liquor 1225 W.Lockeford St.Lodi(SR0055139) <br /> The San Joaquin County Environmental Health Department(EHD)has completed the review of <br /> the amended permit application to include the replaced Incon TPS-ULS sensor in the UDC of <br /> dispenser 1&2 which was tested to pass in the presence of the inspector. In addition to performing <br /> an ISD/EVR phase II upgrade, cold start,&relocation of vent lines to Healy CAS,the permit has <br /> been approved with the following conditions. <br /> Conditions of approval: <br /> 1. Contact the local fire department, local planning or building department and the San <br /> Joaquin Valley Air Pollution Control District for any applicable permits. <br /> 2. Any changes shall be submitted to the San Joaquin County Environmental Health <br /> Department(EHD) for approval prior to commencing work. All new addenda supersede <br /> the previous ones. <br /> 3. All components must be certified by an independent testing organization and labeled as <br /> required by the organization. (UL,ULC, ANSI,API, ASTM,etc. See California Code of <br /> Regulations(CCR),Title 23 Chapter 16 Table B for complete list). The component must <br /> bear the appropriate mark as required by the independent testing organization. <br /> 4. Before the alarm history is cleared by the"cold start",a current printout must be <br /> created and available for EHD inspection. Inspection may occur during the monitoring <br /> system functionality test. <br /> 5. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid, current contractor's licenses issued by the <br /> Contractors State License Board(may be issued to the installation company),and <br /> b. All valid,current California UST certificates issued by the International Code <br /> Council(ICC),that are applicable to the work being performed,and <br /> c. A valid, current certificate of training from the manufacturer(s)of the <br /> component(s)being tested,repaired,or serviced; <br /> d. Each person installing or testing any component must hold a certificate of <br /> training from the manufacturer of that component. <br /> Page 1 of 2 <br />