Laserfiche WebLink
PRASURE-VACUUM VEAS <br /> - - 548 & 548A748 & 748 A <br /> PRESSURE-VACUUM -# ESSURE-VACUUM <br /> VENT VENT <br /> WITH GAUGE HATCH <br /> For"normal"venting of Aboveground Stor- For"normal"venting of Aboveground Stor- <br /> age Tanks. Allows tank to"breath"during age Tanks. Allows tank to"breath"during <br /> filling and withdrawing operations.Pressure- filling and withdrawing operations.Pressure- <br /> vacuum poppets seal vapors in the tank when vacuum poppets seal vapors in the tank when <br /> pressure is equalized. This.vent must be pressure is equalized. This vent must be <br /> FIG 548 used in conjunction with an emergency vent FIG 748 used in conjuction with an emergency vent <br /> and it is RECOMMENDED that the opening and it is RECOMMENDED that the opening <br /> pressure setting is set below that of the emer- pressure setting is set below that of the emer- <br /> gency vent so the normal vent relieves first. gency vent so the normal vent relieves first. <br /> CONSTRUCTION DETAILS CONSTRUCTION DETAILS <br /> FIG 548...................Brass Body and Hood. FIG 748...................Stainless Steel Poppets. <br /> FIG 548 A................Aluminum Body and Hood. FIG 748 A...............Brass Poppets <br /> Standard Features: (Fig 748 available in 2.0 oz/sq in pressure-1.0 oz/sq in Vacuum only) <br /> 1. Brass(raised)metal-to-metal Seats/Poppets. Standard Features: <br /> 2. Threaded Gauge Hatch for manual gauging access. 1. Aluminum Body and Hood. <br /> 3. Horizontal Discharge and field-adjustable,tripolar orientation. 2. Horizontal Discharge with field-adjustable tripolar orientation. <br /> Size Pressure Vacuum Fig 548 Fig 548A Venting Size Pressure Vacuum Fig 748 Fig 748A Venting <br /> Setting Setting Ship Ship Capacity Setting Setting Ship Ship Capacity <br /> (oz/sq in) (oz/sq in) Weight Weight (CFH) (oz/sq in) (oz/sq in) Weight Weight (CFH) <br /> (LBS) (LBS) (@2.5 PSI) (LBS) (LBS) (@2.5 PSI) <br /> 2" 2.0 1.0 13.25 7.00 20,200 2" 2.0 1.0 13.25 7.00 20,200 <br /> 2" 4.0 1.0 13.75 8.75 20,200 2" 4.0 1.0 NA 8.75 20,200 <br /> 2" 6.0 1.0 14.25 8.50 20,200 2" 6.0 1.0 NA 8.50 20,200 <br />-t 2" 8.0 1.0 14.75 9.50 20,200 2" 8.0 1.0 NA 9.50 20,200 <br /> j 2" 12.0 1.0 15.75 10.50 18,600 2" 12.0 1.0 NA 10.50 18,600 <br /> 2" 16.0 1.0 17.00 11.25 18,000 2" 16.0 1.0 NA 11.25 18,000 <br /> l 3" 2.0 1.0 26.25 12.25 43,000 WARNING: Obstruction of airflow through vents can <br />'� 3" 4.0 1.0 27.25 13.75 43,000 g <br /> 3" 6.0 1.0 28.25 15.00 43,000 result in structural deformation of the tank. Atmo- <br /> 3" 8.0 1.0 28.75 15.75 43,000 spheric conditions and below freezing temperatures <br /> 3" 12.0 1.0 29.25 15.75 40,000 may cause condensation to occur and freeze. Freezing <br /> 3" 16.0 1.0 33.25 20.50 40,000 y 9 <br /> action can restrict movement of poppets and block <br />" screened air passages. Monthly inspection and more <br /> L 749 SERIES frequent inspection in cold weather by someone famil- <br /> iar with the proper operation of this vent is required to <br /> help guard against accidental damage to the tank. For <br /> PRESSURE-VACUUM further instructions contact: Morrison Bros. Co. <br /> VENT Dubuque Iowa(319)583-5701. <br /> Vent valve used on underground&low <br /> volume aboveground tanks for motor 748 ALT <br /> fueling. Vent allows tank to"breath" <br /> during filling/dispensing operations. <br /> Poppets seal vapors in the tank whenPRESSURE-VACUUM <br /> pressure is equalized. Settings are VENT <br /> FIG 749 approximate. <br /> Warning:FIG 749 PN Vent must only FOR AG-CHEMICAL <br /> CONSTRUCTION DETAILS be used in conjunction with motor Vent valve used with aqua-amonia and <br /> FIG 749-2"NPT fueling and/or low capacity flow.Fluid ag-chemical products allowing tank to <br /> handling in lines largerthan that used 'breathe"during loading/unloading op- <br /> FIG 749 S-2"Slip-on style for retail service station can cause erations. Poppets seal vapors in the <br /> FIG 748 ALT <br /> FIG 749 CRB-2"NPT tank to rupture or implode. tank when pressure is equalized. Set- <br /> tings are approximate. <br /> 4 C.A.R.B.approval(95-15A) Pressure Vacuum Ship Venting CONSTRUCTION DETAILS <br /> for Stage I and II.Viton 0-rings Setting Setting Weight Capacity Size....................................2"NPT <br /> on pressure poppet. (oz/sq in) (oz/sq in) (LBS) (CFH) Body and Cap...............Aluminum Pressure Vacuum Ship Venting <br /> (@2.5 PSI) Poppets.........Teflon Coated Alum Setting Setting Weight Capacity <br /> Body..................... Aluminum FIG 749&749 S Screens.................Stainless Steel Ibs/s m oz/s in <br /> ( q� )( 4� ) (LBS) (CFH) <br /> Pressure Poppet...Aluminum 8.0 0.5 1.0 8,500 (@2.5 PSI) <br /> Vacuum Po 12.0 0.5 1.0 8,500 <br /> ppet.......... Brass FIG 749 CRB Option: (Must specify) male 0.5 1.0 5.5 20,200 <br /> Seal........................... Buna-N 3"W.C. 8"W.C. 1.2 NPT connection for dryer appli- 1.0 1.0 5.5 18,000 <br /> Screen...........................Brass 8 oz. 5 oz. 1.2 cation. <br /> 2.0 1.0 6.0 NA <br /> 25 <br />