1/14/1999 <br />Circle "K" 04176 <br />950 W 11`h St. <br />Tracy CA 95376 <br />Review Notes from San Joaquin County Environmental Health (PHS/EHD): <br />PHS/EHD contact Steven Sasson (209) 468-3459 <br />This plan appears to be for a system upgrade using the existing double wall <br />fiberglass tanks installed in 1988. All additional equipment will be replaced with new. <br />The plans also appear to be generic. Please amend plans to reflect this particular <br />installation including equipment part lists, details and all drawings. Please delete (or <br />cross out) all references to equipment which is not to be installed. <br />1) Piping: <br />The plans call for A.O. Smith or Ameron FRP. Manufacturer specifications have <br />been submitted for CTC piping. It is unclear if this piping is flexible hose or hard <br />piping or a combination. Please submit a UL listing, fuel compatibility and <br />installation instructions for CTC piping. Please confirm brand of piping to be used <br />on site (AO Smith, Ameron or CTC). Please amend plans and manufacturers <br />specifications (cut sheets) to reflect piping for this site. <br />There is no piping layout in the prints. Please provide a print of the piping layout <br />including pipe diameters for primary and secondary piping, vent piping, slopes, <br />pipe composition, and corrosion protection for corrosion susceptible piping in <br />contact with backfill. Please augment section 7.5 of Installation Instructions to <br />include all corrodible underground piping. Only fiberglass piping will be approved <br />for vent piping. <br />2) Monitoring System: <br />Line Leak Detector- Prints call for Vaporless LD 2000. You have submitted cut <br />sheets for veeder root. The cut sheets do not include the part number (p/n). Please <br />submit cut sheet with p/n (i.e. 8494, 8484, 8475) please amend plans to reflect LLD <br />to be used at this site. <br />Interstitial Probe- Veeder Root 794390-401 Please submit cut sheet with p/n <br />Turbine Sump Probe (Piping Probe)-Veeder Root 794380-351 This sensor is not <br />listed in SWRCB LG 113-12. Please choose a probe that has been recognized by <br />SWRCB, or provide SWRCB evaluation for this device. Please provide cut sheets <br />with p/n for either. <br />3) Overfill- EMCO Wheaton Guardian A-1100 shall be installed to provide positive <br />shut off at equal to or less than 95% capacity. <br />4) Containment Sumps- Plans call for Xerxes. You have submitted cut sheets for <br />CTC. If CTC is used please provide UL Listing and statement of compatibility <br />with existing tanks. Please amend prints to reflect actual equipment to be installed <br />at this site. <br />