Laserfiche WebLink
► Ultrasonic technology determines presence <br />of fluid and alarms at low level and high level <br />"trip" points. <br />► Conductive elastomer differentiates between <br />hydrocarbons and other liquids and alarms <br />when hydrocarbon is detected at any point on <br />the sensor. <br />► Accurate, reliable and reusable even after <br />exposure to heavy concentrations of hydro- <br />carbons. <br />► Long -life, durable construction withstands <br />even the most harsh environments. <br />Veeder-Root's Dispenser Pan and Containment Sump <br />Sensors quickly and accurately detect the presence of <br />hydrocarbons or fluids and differentiate between the two, <br />in their respective locations. <br />Alarm conditions — Fuel, Liquid Warning, High Liquid Alarm, <br />Sensor Out — detected by either sensor are indicated by <br />an audible alarm, a displayed message, and a printed <br />message on the on the TLS -350R or TLS -350. They are <br />also recorded as part of the TLS -350R or TLS -350 Alarm <br />History Report. <br />Durable and accurate, the Dispenser Pan and Containment <br />Sump Sensors have no moving parts to wear out or stick. <br />The sensors also withstand harsh environments; they <br />continue to detect fluid and hydrocarbons accurately — <br />even in freezing temperatures. <br />The housing is constructed of polyester, the sensing <br />element a conductive elastomer. The sensors can be <br />reused after an alarm condition is sensed, without degrada- <br />tion to the sensing materials. Remove the sensor, allow it to <br />dry, then reinstall for the same reliable sensing as when it <br />was new. <br />The Dispenser Pan and Containment Sump Sensors are <br />easily installable in most pans and sumps using the pan <br />and sump manufacturers' installation brackets. <br />The Dispenser Pan and Containment Sump Sensors are <br />warranted to be free from material defects for a period of <br />one year from the date of installation or 15 months from the <br />date of invoice. <br />Detection Capabilities <br />► Sensor Alarm Conditions; <br />• Fuel at any height on the sensor even when <br />floating on other liquid, triggers a Fuel Alarm. <br />• Liquid Warning is triggered when liquid reaches <br />1.0" high on both Dispenser Pan and Contain- <br />ment Sump Sensors. <br />• High Liquid Alarm is triggered when liquid <br />reaches 8.0" on Dispenser Pan Sensor 10" on <br />Containment Sump Sensors. <br />► Sensor should be tested in liquid at least once a <br />year or as required by local codes. <br />Operating Capabilities <br />► Operating Temperature Range: - 40°C to +70°C. <br />► Storage Temperature Range: - 40°C to +70°C. <br />► Cable Length: 6 feet. <br />► Dispenser Pan Sensor Dimensions: 11.53" high, <br />2.13" diameter <br />► Containment Sump Sensor Dimensions: 22.03" <br />high, 2.13" diameter. <br />► Withstand removal and replacement from sensing <br />environment without sensor damage. <br />Veeder-Root's <br />L --- <br />premium line of <br />sensors engineered <br />to distinguish liquid hydrocarbons from water, <br />utilizing the best sensing technologies available. <br />