My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
950
>
2300 - Underground Storage Tank Program
>
PR0231401
>
COMPLIANCE INFO_2005-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:48:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2012
RECORD_ID
PR0231401
PE
2361
FACILITY_ID
FA0006388
FACILITY_NAME
KWIK SERVE
STREET_NUMBER
950
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23406002
CURRENT_STATUS
01
SITE_LOCATION
950 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231401_950 W ELEVENTH_2005-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
385
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dec 16 04 04:51p Cr.@CL CR <br />Introduction <br />916m&91-1177 p.3 <br />Tracer Tight® Method <br />of Tightness Testing for <br />Underground Storage Tank Systems <br />in Accordance With <br />Section 2644.1 <br />Enhanced Leak Detection <br />Section 2644.1 clarifies that "Enhanced" leak detection means a test method that <br />ascertains the physical integrity of an underground tank system by introduction, and <br />external detection, of a substance that is not a component of the fuel formulation that is <br />stored in the tank system." It further requires that the "test method shall be third party <br />certified, in accordance with section 2643(f), for the capability of detecting both vapor <br />and liquid phase releases from the underground storage tank system. The enhanced leak <br />detection test method shall be capable of detecting a leak rate of at least 0.005 gph or <br />less, with a probability of detection of at least 95% and a probability of false alarm no <br />greater than 5%." <br />Concept <br />Tracer Tight® is a unique method of testing underground storage systems for tightness. A <br />unique chemical called a tracer is added to the product stored in the tank. The tracer is an <br />inert chemical that evaporates readily from the fuel. After tracer is added to the system, it <br />is distributed between the vapor and liquid inside the tank. Use of the system carries the <br />tracer throughout the piping. If any small leak exists in the system, the tracer is allowed <br />to escape from the system, either as a vapor or as a dissolved component of the liquid. <br />Once outside the system, the dissolved tracer evaporates from the liquid and the tracer <br />vapors begin to migrate away from the location of the leak in all directions. After an <br />appropriate waiting period, the tracer vapors are detectable at least ten feet or more away <br />from the leak in all directions. Samples of air collected from the soil within the radius of <br />detection of the tracer reveal the leak as a presence of the tracer chemical. Because the <br />tracer chemical is not normally found in the environment or in fuel products, the Tracer <br />Tight® method is able to discriminate between previous contamination and current <br />leakage. <br />
The URL can be used to link to this page
Your browser does not support the video tag.