Laserfiche WebLink
SWRCB,January 2002 Page '5 of <br /> ?. ER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: D UDC Manufacturer 0 Industry Standard X Professional Engineer <br /> D Other(Spec) <br /> Test Method Used: D Pressure 0 Vacuum X Hydrostatic <br /> 0 Other(Specify) <br /> Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br /> " UDC#1&2' UDC#3&4 UDC#5&6 UDC#7&8 <br /> UDC Manufacturer. APT APT APT APT <br /> UDC Material: Poly Poly Poly Poly <br /> UDC Depth: 28" 29" 28" 28" <br /> Height from UDC Bottom to Top 13" 13" 13" 13" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 6" 61/2" 5 %2" 6" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Dry Dry Dry Dry <br /> testing: <br /> Portion of UDC Tested Water Level'16" Water Level 16" Water Level 16" Water Level 16" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both X Yes No 0 NA X Yes No D NA X Yes No D NA X Yes No 0 NA <br /> product and water)?` <br /> Turbine shutdown response time Not Alarmed Not Alarmed Not Alarmed Not Alarmed <br /> Is system programmed for fail- X Yes 0 No 0 NA X Yes 0 No DNA X Yes 0 No DNA X Yes 0 No DNA <br /> safe shutdown?" <br /> Was fail-safe verified to be Yes X No DNA Yes X No DNA Yes X No DNA Yes X No DNA <br /> operational?* <br /> Wait time between applying 5 Minutes 5 Minutes 5 Minutes _5Minutes <br /> water and starting test <br /> Test Start Time: 9:25 9:35 10:10 10:15 <br /> Initial Reading(R�: .001 .001 .001 .001 <br /> Test End Time: 9:55 10:05 10:40 10:45 <br /> Final Reading(RF): .001 .001 .001 .001 <br /> Test Duration: 30 Minutes 30 Minutes 30 Minutes 30 Minutes <br /> Chane in Reading(RF-RF): 0 0 0 0 <br /> Pass/Fail Threshold or Criteria: .005/30 Minutes .005/30 Minutes .005/30 Minutes .005/30Minutes <br /> Test Result: X Pass 0 Fail X Pass 0 Fail X Pass ❑Fail X Pass D Fail <br /> Was sensor removed for testing? X Yes D No DNA X Yes D No 0 NA X Yes 0 No 0 NA X Yes 0 No 0 NA <br /> Was sensor properly replaced and X Yes 0 No D NA X Yes D No 0 NA X Yes D No D NA X Yes D No D NA <br /> verified functional after testing! <br /> Comments—(include information on repairs made prior to testing and recommended follow-up for failed tests) <br /> 1 If the entire depth of the UDC is not tested,specify how much was tested. If the answer to My of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />