My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2005-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
950
>
2300 - Underground Storage Tank Program
>
PR0231401
>
COMPLIANCE INFO_2005-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:19:32 AM
Creation date
6/3/2020 9:48:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2012
RECORD_ID
PR0231401
PE
2361
FACILITY_ID
FA0006388
FACILITY_NAME
KWIK SERVE
STREET_NUMBER
950
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23406002
CURRENT_STATUS
01
SITE_LOCATION
950 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231401_950 W ELEVENTH_2005-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
385
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web;www.sigov.org/ehdtunitiii.htmi <br /> CONTINUATION FORM Page: 3 of 3 <br /> OFFICIAL INSPECTION REPORT Date: 08/17/11 <br /> Facility Address: Kwik Serve 950 West Eleventh Street, Tracy, 95376 Program: UST <br /> SUMMARY OF VIOLATIONS <br /> CLASS I CLASS II,or MINOR-Notice to Comply) <br /> UST Inspection: Routine and Annual Monitoring System Certification testing <br /> 2. Secondary containment testing was last performed on 05/02/2008 and was due by May 2011. <br /> Testing has not been completed and is three months past due. Secondary containment testing is <br /> required once every 36 months. Immediately schedule this test and provide 48 hours notification to the <br /> EHD. Submit test results within 30 days of testing. <br /> 21. Moisture and wet/dampness was felt by the technician at least two feet length of the diesel annular <br /> sensor. There was no odor, oily texture nor visual color appearance of fuel on the wrap around diesel <br /> annular sensor. There could be a high possibility that there is liquid in the diesel annular space. Per <br /> technician, there could be approximately one cup of liquid. In addition, there were two L4 diesel annular <br /> sensor out alarms on July 22 and June 6, 2011 which both had cleared itself which could be an <br /> indication that liquid could have triggered the sensor momentarily. If water could enter into the <br /> secondary containment by precipitation or infiltration, it must be removed and disposed of properly. <br /> Immediately remove this liquid, make a hazardous waste determination per Title 22 hazardous waste <br /> regulations, and manage it accordingly. Investigate the source of how the liquid could enter into the <br /> diesel annular space. Ensure that the all annular space is maintained free of liquid. Submit a copy of the <br /> work order or supporting document that liquid was removed from the diesel annular space. <br /> 23c. The designated operator failed to check and note the correct test dates for the secondary <br /> containment testing on the designated operator monthly inspection reports from October 2010 to <br /> present, July 2011. The designated operator noted the secondary containment testing as 05/02/2010. <br /> The correct test date is 05/02/2008. During the monthly inspection, the designated operator shall <br /> check that all required testing and maintenance for the UST system have been completed and document <br /> the dates they were done. Ensure that designated operators performing monthly inspections at this <br /> facility are including all of the required information on the reports. Submit a statement how to ensure the <br /> test date is correctly documented. <br /> Submit to SJC EHD within 30 days (09/19/11)- <br /> 1. one copy of the completed "Return to Compliance Certification" form <br /> 2. a written corrective action statement for each of the above violations <br /> 3. requested/supporting documentation ie. work order <br /> Notes: - Next Designated operator employee training due by 11/2011 <br /> - Provided free training schedule. Recommended courses: UST for Owners, Hazardous & Universal <br /> Waste management. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Inspector: Received By: Title: <br /> EHD 23-02-003 Rev 0 2111 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.