My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2008
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2006-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2024 4:11:28 PM
Creation date
6/3/2020 9:48:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2008
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2006-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
19255517888 Main Fax GETTLER RYAN INC 09:08:04 a.m <br />D. Ilesults of Testing/Servicing <br />J <br />Software Version Installed: <br />Complete the following cheeklict! <br />10-03-2007 3/4 <br />X Yes <br />❑ No* <br />Is the audible alarm o rational? <br />X Yes <br />❑ No* <br />Is the visual alarm operational? <br />❑ Yes <br />X No* <br />Were all sensors visually inspectA functionally tested, and confirmed ional?L16 ONLY STP <br />❑ Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment wi0 <br />not interfere with their pMer o tion?87 OCT ONLY STP <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />X N/A <br />operational? <br />X Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: }ghich sensors initiate <br />positive shut -down? (Check all that apply) X Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? X Yes; ❑ No <br />❑ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />X N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill int(s) and operating rol ? If so, at what percent of tank does the alarm trigger? % <br />X Yes* <br />❑ No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer time and model for all r lacement 2arts in Section E below. <br />❑ Yes* <br />X No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) ❑ <br />Product; ❑ Water. If es, describe causes in Section E, below. <br />Yes <br />X No* <br />Was monitoring system "reviewed to ensure pro2E settin ? Attach set up reports, if applicable <br />Yes <br />X No* I <br />Is all monitorin went o onal per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were "ll be corrected. <br />E. Comments: _L16 SENSOR REPLACED & TESTED 87 SIPHON STP SUMP ONLY.. <br />Page 2 of 3 03/01 <br />'Del~.J <br />Dele <br />
The URL can be used to link to this page
Your browser does not support the video tag.