Laserfiche WebLink
.l <br /> µ,�- x.31•�K <br /> Ask <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION(One form per UST) <br /> TYPE OF ACTION (Check one item only. For an UST permanent closure or removal,complete only this section and Sections I,II,III,IV,and IX below) 430 <br /> ® 1.NEW PERMIT ❑ 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430a DATE EXISTING UST DISCOVERED: 430b <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 1 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) WV 3 <br /> ARCO 02093SAN-10AQUIAIWUNTY104 <br /> BUSINESS SITE ADDRESS 103 TTITY OFFICE OF EMERGENCY SERVICES <br /> 3425 TRACY BLVD I TRACY <br /> II.TANK DESCRIPTION <br /> TANK ID# 2 432 TANK MANUFACTURER 433 TANK CONFIGURATION: THIS TANK IS 434 <br /> Xerxes ® 1.A STAND-ALONE TANK <br /> ❑2.ONE IN A COMPARTMENTED UNIT. <br /> Complete one page for each compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437 <br /> 1993/07 10,000 1 <br /> III.TANK USE AND CONTENTS <br /> TANK USE ® la.MOTOR VEHICLE FUELING ❑ lb.MARINA FUELING ❑ lc.AVIATION FUELING 439 <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Includes Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§25281.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 439a <br /> CONTENTS PETROLEUM: ® la.REGULAR UNLEADED ❑ la MIDGRADE UNLEADED ❑ lb.PREMIUM UNLEADED 440 <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑ 8.PETROLEUM BLEND FUEL ❑ 9.OTHER PETROLEUM (Specify): 44oa <br /> NON-PETROLEUM:❑ 7.USED OIL ❑ 10.ETHANOL <br /> ❑ 4aob <br /> 11.OTHER NON-PETROLEUM(Specify): <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 95.UNKNOWN 443 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444 <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER (Specify): 444a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445 <br /> ❑ 90.NONE ❑ 95.UNKNOWN [199.OTHER(Specify): 445a <br /> OVERFILL PREVENTION ® 1.AUDIBLE&VISUAL ALARMS ® 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑1.SINGLE-WALLED ®2.DOUBLE-WALLED ❑99.OTHER 460 <br /> SYSTEM TYPE ® 1.PRESSURE ❑ 2.GRAVITY ❑ 3.CONVENTIONAL SUCTION ❑ 4.SAFE SUCTION[23 CCR§2636(a)(3)] 458 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464 <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464a <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 8.FLEXIBLE ❑ 10.RIGID PLASTIC 464b <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464c <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI.VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ L STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 464e <br /> 464el <br /> VENT SECONDARY CONTAIN ENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 464f <br /> 464fl <br /> VR PRIMARY CONTAINMENT ❑ L STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4648 <br /> 464 1 <br /> VR SECONDARY CONTAINMENT ❑ 1.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 464h <br /> 464h1 <br /> VENT PIPING TRANSITION SUMP TYPE ❑ 1.SINGLE WALL ❑ 2.DOUBLE WALL ® 90.NONE 4641. <br /> RISER PRIMARY CONTAINMENT ® L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4641 <br /> 464'1 <br /> RISER SECONDARY CONTAINMENT ❑ L STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify) 464k <br /> 464k1 <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3.STRIKER PLATEBOTTOM PROTECTOR ® 4.CONTAINMENT SUMP 45la-c <br /> VII.UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE ® 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 3.NO DISPENSERS ❑ 90.NONE 469a <br /> CONSTRUCTION MATERIAL ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99.OTHER(Specify) 469b-c <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certifAthat'i T ystem is compatible with the hazardous substance stored and that the information provided herein is true,accurate, <br /> co <br /> m with legal requirements. <br /> andin 4 <br /> APPLICANT SIGNATURE DATE 12/16/08 470 <br /> APPLICANT NAME(print) BRATZO SAGOITIA 471. APPLICANT TITLE Environmental Compliance Specialist 472' <br /> ARCO 02093,BELSHIRE ENVIRONMENTAL SERVICES PAGE 3 OF 5 UPCF UST-A Rev.(12/2007) <br />