My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:04:04 PM
Creation date
6/3/2020 9:48:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Item#206 <br /> |nyour remarks,you ask us to "immediately obtain a permit from the EHD for the replacement of the L5 <br /> sensor." However, according to your department's policy(attached),a "like-for-like" replacement of a liquid sensor <br /> does not require a permit but requires notification. Please confirm that notification only will suffice toclose this <br /> violation. <br /> Thank you, <br /> Daryl Lee <br /> Retail Compliance Coordinator <br /> 89—Fuels North America <br /> 415.902.5089 <br /> From: Lee, Daryl <br /> Sent: Thursday, SeptemberU6. 2018 1:08 PM <br /> To: Zunal Barker [EH] <br /> Subject: RE: inspection report <br /> Good Morning Zuna. Thank you for the report. | sent acopy ofthe report tuJeff TagUareniwith Ge|shire. |dowant to <br /> clarify efew items with you: <br /> Item#308ĵ <br /> These two items cite the same regulation in effect-#309 cites CCR 2636(f)(1)which is a sub-requirement of CCR 2636(f) <br /> and according to the text of the two regulations they are saying the same thing(in fact(f) is a lead-in to (f)(1)). May | ask <br /> why then are xxebeing issued two separate violations? <br /> Item#314 <br /> TheT2regu|arpipevvasrepairedbyGett|epKyan, |nc. on3/16/18,andretestedbyGett|epRyan, |nc. on <br /> 3/27/18. Gett|epRyannoti0edyourdepartnnentpriortotheretest(attauhed), hoxvevertheteytdatafurthepipingvvay <br /> not included inthe test report sent toyour department(a1tached). (]nbehalf ofGett|er-Ryan, | apologize for this <br /> error. Will you accept the 3/37/18 test results with the piping data included? <br /> Thank you, <br /> Daryl Lee <br /> Retail Compliance Coordinator <br /> 8P—Fuels North America <br /> 415.902.5089 <br /> From: Zuna ]. Barker [EH] <br /> Sent: Friday, August 31, 2018 10:07 AM <br /> To: Lee, Daryl <br /> Subject: FW: inspection report <br /> Please find attached to this email the inspection report for the LIST routine inspection conducted yesterday. <br /> While I was on site I met Jeff Tagliareni, regional manager,from Belshire and he asked for a copy of the report. I have <br /> not email him a copy of the report because I was not sure if you be okay with me emailing it to him. I do not mind <br /> sending him a copy but I would need an okay from you before I do so. Please do not hesitate to give me a call if you have <br /> any questions. <br /> 4 <br />