COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3425
>
2300 - Underground Storage Tank Program
>
PR0231416
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:04:04 PM
Creation date
6/3/2020 9:48:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231416
PE
2361
FACILITY_ID
FA0003627
FACILITY_NAME
ARCO 02093
STREET_NUMBER
3425
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
21418020
CURRENT_STATUS
01
SITE_LOCATION
3425 TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231416_3425 TRACY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
599
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 1 of 1 <br /> 8.FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps 17. <br /> Fill Riser Containment Sumps are Present,but were Not Tested <br /> Test Method Developed By: F! Sump Manufacturer F�,, Industry Standard F" Professional Engineer <br /> f7' Other(Specify) <br /> Test Method Used By: Pressure vacuum � Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used:VPLT Equipment Resolution:0.00001 in. <br /> Fitt Gontaitinent for Fill Containment for Fill Containment for'' FitI'Containment for <br /> Tank T 1 REGULAR: , Tank T-2 REGULAR- Tank T-3 REGULAR-., Tank T-4,PREMIUM- <br /> l <br /> Sump Diameter: 48.00 in. 48.00 in. 48.00 in. 48.00 in. <br /> Sump Depth: 73.00 in. 73.00 in. 73.00 in. 73.00 in. <br /> Height from Tank Top to Top of 0.00 0.00 0.00 0.00 <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 43.00 43.00 43.00 43.00 <br /> Electrical Penetration: <br /> Condition of sump prior to testing: good good good good <br /> Portion of Sump Tested 47 47 47 47 <br /> Sump Material Fiberglass Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 min 5 min 5 min 5 min <br /> test <br /> Test Start Time: 10:44:00 10:01:00 11:25:00 12:09:00 <br /> Initial Reading(Rt): 0.00000 in. 0.00000 in. 0.00000 in. 0.00000 in. <br /> Test End Time: 11:14:00 10:31:00 11:55:00 12:39:00 <br /> Final Reading(RF): -0.00190 in. -0.00020 in. -0.00040 in. -0.00120 in. <br /> Test Duration: 30 min 30 min 30 min 30 min <br /> Change in Reading(RF-R,): -0.00190 in. -0.00020 in. -0.00040 in. -0.00120 in. <br /> Pass/Fail Threshold or Criteria: +/-0.00200 +/-0.00200 +/-0.00200 +/-0.00200 <br /> TestRestl _ Pass..., . Pass... <br /> Is there a sensor in the pump? f++ Yes r No 49 Yes No ( Yes No G Yes rF No <br /> Does the sensor alarm when either Yes( No M NA Q Yes(7 No(" NA ( Yes r No r NA <br /> Yes(" No( NA <br /> product or water is detected? <br /> Was sensor removed for testing? Q Yes t" No M NA 6 Yes M No r NA 9 Yesr Nor NA Yes t"" No tx' NA <br /> Was sensor properly replaced and Yes f No NA r G Yes('' No NA ( f Yes r No NA r Yes r No NA f7 <br /> verified functional after testing? <br /> Comments-(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> WO:2335159 <br />
The URL can be used to link to this page
Your browser does not support the video tag.