Laserfiche WebLink
T 4:DIESEL <br />PRODUCT CODE 4 <br />THERMAL COEFF :.000450 <br />0 2:PLUS <br />TANK DIAMETER 92.00 <br />LEAK TEST METHOD <br />TANK PROFILE 4 PTS <br />_ _ <br />TYP:'2.0,3.OIN FIBERGLASS <br />FULL VOL 11627 <br />_ _ <br />TEST C:SLD ALL TANK <br />2.01N DIA LEN: 200 FEET <br />69.0 INCH VOL 9301 <br />Pd = 99% <br />46.0 INCH VOL : 5683 <br />CLIMATE FACTOR : MODEkATE <br />3.OIN DIA LEN: 0 FEET <br />23.0 INCH VOL : 2103 <br />METER DATA : NO <br />GROSS TEST <br />0.20 GPH TEST: REPETITIV <br />AUTO -CONFIRM: DISABLED <br />0.10 GPH TEST: AUTO <br />SHUTDOWN RATE: 3.0 GPH <br />FLOAT SIZE: 4.0 IN. <br />REPORT ONLY: <br />LOW PRESSURE SHUTOFF:NO <br />DISABLED <br />LOW PRESSURE 0 PSI <br />WATER WAkNING 1.0 <br />HIGH WATER LIMIT: 2.0 <br />TST EARLY STOP:DISABLED <br />T 2:PLUS 89 <br />DISPENSE MODE: <br />MAX OR LABEL VOL: 11627 <br />LEAK TEST REPORT FORMAT <br />STANDARD <br />OVERFILL LIMIT 95% <br />SEAPRESSURE <br />11045 <br />NORMAL <br />PRESSURE OFFSET: O.OPSI <br />HIGH PRODUCT 980% <br />11394 <br />DELIVERY LIMIT 15% <br />1744 <br />LOW PRODUCT 500 <br />LEAK ALARM LIMIT: 3 <br />SUDDEN LOSS LIMIT: 50 <br />TANK TILT 5.25 <br />PROBE OFFSET 0.00 <br />PRESSURE LINE LEAK SETUP <br />SIPHON MANIFOLDED TANKS <br />- _ - - - _ � - - - - <br />G 3:PREMIUM <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />0 I:REGULAR <br />TYP:2.0,'3<OIN FIBERGLASS <br />TO: NONE <br />2,0IN DIA LEN: 200 FEET <br />TYP:2-0/3.0IN FIBERGLASS <br />3.0IN DIA LEN: 0 FEET <br />LEAK MIN PERIODIC: 0% <br />2.0IN DIA LEN: 200 FEET <br />0 <br />3.0IN DIA LEN: 0 FEET <br />0.20 GPH TEST: REPETITIV <br />0.10 GPH TEST: AUTO <br />., LEAK t°IIN ANNUAL 0% <br />0,20 GPH TEST: REPETITIV <br />SHUTDOWN RATE: 3.0 GPH <br />' 0 <br />0.10 GPH TEST: AUTO <br />LOW PRESSURE SHUTOFF:NO <br />SHUTDOWN RATE: 3.0 GPH <br />LOW PRESSURE : 0 PSI <br />PERIODIC TEST TYPE <br />LOW PRESSURE SHUTOFF:NO <br />T 3:PREMIUM 91 <br />STANDARD <br />LOW PRESSURE : 0 PSI <br />DISPENSE MODE: <br />ANNUAL TEST FAIL <br />T I:REGUL.AR 87 <br />STANDARD <br />SENSOR: HIGH PRESSURE <br />ALARM DISABLED <br />DISPENSE MODE: STANDARD <br />PRESSURE OFFSET: O.OPSI <br />PERIODIC TEST FAIL <br />SENSOR: HIGH PRESSURE <br />ALARM DISABLED <br />PRESSURE OFFSET: O.OPSI <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIF`!: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />